{"product_id":"honeywell-cc-paiho1-high-density-16-port-ai-module-c300","title":"Honeywell CC-PAIHO1 High-Density 16-Port AI Module C300","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PAIHO1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analog input module engineered for the Honeywell Experion PKS C300 controller environment. This module provides 16 isolated channels designed to interface with process transmitters, sensors, and field instrumentation. By converting critical analog field data into precise 16-bit digital signals, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PAIHO1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables the C300 controller to execute complex control loops with high accuracy and deterministic response times.\u003c\/p\u003e\n\u003cp\u003eDesigned for the technical rigors of industrial processing, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PAIHO1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both current (4–20 mA) and voltage (0–10 VDC) signal types. It features robust galvanic isolation across all channels to prevent ground loops and electromagnetic interference (EMI) from degrading signal integrity. We provide this module as 100% brand new and factory-original, ensuring maximum reliability for your plant’s control architecture.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell (USA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PAIHO1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Analog Input Module (AI)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eController Platform\u003c\/strong\u003e: Experion PKS C300\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: 16 Isolated Inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Range (Current)\u003c\/strong\u003e: 4–20 mA, 0–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Range (Voltage)\u003c\/strong\u003e: 0–10 VDC, 1–5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e: 16-bit Resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.1% of Full Scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e: 250 Ω (current mode)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: Channel-to-channel and channel-to-system isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Open-circuit detection, over\/under-range monitoring, and board-level health checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e: 5% to 95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 6.8 cm x 10.7 cm x 7.8 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.59 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e: CE, UL, CSA, Conformal Coating (G3 compatible)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Channel Density\u003c\/strong\u003e: The 16-channel architecture allows for significant cabinet space savings, reducing the footprint of the I\/O rack while maintaining individual channel isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Diagnostic Feedback\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PAIHO1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides real-time status reporting to the Experion PKS software, allowing maintenance teams to identify failing transmitters or wiring faults before they impact process safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Processing\u003c\/strong\u003e: Optimized for the C300 Series, the module ensures that analog data is updated in the controller database within millisecond timeframes, supporting high-speed control requirements in sectors like power and petrochemicals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CC-PAIHO1 support HART protocol pass-through?\u003c\/strong\u003eStandard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PAIHO1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules are optimized for high-speed analog sensing. For applications requiring HART digital asset management, verify if the specific PWA revision or a HART-enabled variant is required for your IOTA baseplate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module hot-swappable in a C300 rack?\u003c\/strong\u003eYes, when utilized within a redundant C300 I\/O configuration, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PAIHO1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be replaced while the system is powered and the process is running, provided the secondary module is active.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific I\/O Termination Assembly (IOTA)?\u003c\/strong\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PAIHO1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be seated on a compatible C300 IOTA baseplate to facilitate field wiring connections and system power distribution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44079199780963,"sku":"CC-PAIHO1","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/366.3_53a00c92-7db3-4343-be91-ad23b04e66ee.jpg?v=1774489348","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-cc-paiho1-high-density-16-port-ai-module-c300","provider":"AutoControl Global","version":"1.0","type":"link"}