{"product_id":"honeywell-cc-pdod51-series-c-32-channel-digital-output-module","title":"Honeywell CC-PDOD51 Series C 32-Channel Digital Output Module","description":"\u003ch2\u003eHoneywell CC-PDOD51 Series C Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density discrete control in Experion PKS Series C platforms, the \u003cstrong\u003eHoneywell CC-PDOD51\u003c\/strong\u003e (\u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e Digital Output Module) provides direct physical execution of 32 sink-type output signals.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PDOD51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e50.8 x 177.8 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e32-Channel Sink (Open Drain)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e utilizes a 24 VDC sink architecture to interface with field-level discrete components. Precise control loop execution within the Experion PKS framework relies on the module's electronic over-current protection to prevent bus-side disruption during field-side short-circuit events. The module maintains 1000 VAC RMS system-to-field galvanic isolation, ensuring that common-mode electrical noise from field instrumentation remains decoupled from the process controller bus. When deploying in dense I\/O configurations, users must verify the load current remains within the 0.1 A per-channel limit. Furthermore, conformal coating application provides chemical and moisture resistance, ensuring the module sustains operational integrity under varying industrial atmospheric conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the CC-PDOD51 capable of hot-swapping within the I\/O chassis?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The Series C architecture supports module replacement while the I\/O bus remains powered, provided the corresponding control strategy has been configured for fault-tolerant maintenance.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module detect field-side open circuit or short circuit conditions?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates electronic over-current protection. While it prevents physical damage from shorts, diagnostic feedback for specific field-wire faults depends on the integrated IOTA baseplate and Experion control software configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module interface with loads exceeding 30 VDC?\u003c\/p\u003e\n\u003cp\u003eA: No. The maximum load voltage is 30 VDC. Exceeding this rating will cause the output transistors to fail, leading to permanent module damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the \u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e firmly onto the compatible CC-TDOD51 or CC-TDOD61 IOTA baseplate. Ensure the module locking mechanism clicks into position to guarantee electrical continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route field signals through the IOTA terminals. Maintain separation between 24 VDC output lines and high-voltage AC cabling to mitigate electromagnetic interference coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the IOTA baseplate chassis is connected to a low-impedance earth ground to maintain the effectiveness of the galvanic isolation barrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e Perform a point-to-point check using the Experion engineering station to verify output state transitions and ensure the physical loads operate at the expected logic levels.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43853884424291,"sku":"CC-PDOD51","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/202_66427ec1-095d-415e-938d-f9d6db7e5d50.jpg?v=1764055707","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-cc-pdod51-series-c-32-channel-digital-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}