{"product_id":"honeywell-cc-pui031-experion-pks-uio-module-usa-original","title":"Honeywell CC-PUI031 Experion PKS UIO Module USA Original","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PUI03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a highly versatile Universal Input\/Output (UIO) module designed for the Honeywell Experion PKS Series-C hardware platform. This module represents a significant advancement in I\/O flexibility, allowing each of its channels to be software-configured as an analog input, analog output, digital input, or digital output. By utilizing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PUI03\u003c\/strong\u003e, plant engineers can significantly reduce hardware complexity, optimize cabinet space, and lower the spare parts inventory required for diverse field device signals.\u003c\/p\u003e\n\u003cp\u003eEngineered for the C300 controller environment, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PUI03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports precise signal processing for analog (4–20 mA), discrete (24 VDC), and pulse signals. Its robust architecture includes integrated galvanic isolation and advanced diagnostics, ensuring that field-side faults are detected before they impact process uptime. This module is ideal for high-density control applications where signal types may vary or evolve during the project lifecycle. We provide this unit as 100% brand new and original factory equipment, ensuring maximum authority and trust for your DCS infrastructure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell (USA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PUI03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(also referenced as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PUI031\u003c\/strong\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Universal Input\/Output (UIO)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform compatibility\u003c\/strong\u003e: Experion PKS Series-C \/ C300 Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e: Software-selectable per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Signal Types\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog Input (4–20 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog Output (4–20 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital Input (24 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital Output (24 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Resolution\u003c\/strong\u003e: 16-bit A\/D and D\/A conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: Channel-to-system galvanic isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20 °C to +55 °C (Nominal) \/ Extended up to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e: 5% to 95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 5.5 x 16 x 14.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.4 kg (Net) \/ Shipping Weight 0.8–1.0 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e: CE, UL, CSA, G3 Conformal Coating compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLate Binding Flexibility\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PUI03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for \"late binding\" in engineering projects. Field wiring can be completed before final signal types are defined in software, drastically reducing project schedule risks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace Optimization\u003c\/strong\u003e: By consolidating multiple specialized module types into a single\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PUI03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efootprint, users can reduce the number of I\/O racks and associated power supplies required in the control room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProactive Maintenance\u003c\/strong\u003e: Integrated diagnostics monitor channel health and signal integrity in real-time. Faults such as open wires or short circuits are reported directly to the Experion PKS console, facilitating rapid root-cause analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CC-PUI03 support HART communication?\u003c\/strong\u003eStandard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PUI03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules focus on universal signal flexibility. For full HART digital asset management integration, please verify if your specific Series-C IOTA baseplate and firmware revision support HART pass-through for universal channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix analog and digital signals on the same module?\u003c\/strong\u003eYes. Each channel is independently configurable. For example, you can have 8 analog inputs and 8 digital outputs running simultaneously on a single\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PUI03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between CC-PUI03 and CC-PUI031?\u003c\/strong\u003eThese designations typically refer to the same functional hardware unit within the Series-C UIO family, with the \"1\" often denoting specific PWA revision levels or packaging variations for different global regions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44079640641635,"sku":"CC-PUI03","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/74_e7c88e32-2b53-4f58-b029-4e49b8878aa3.jpg?v=1774491653","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-cc-pui031-experion-pks-uio-module-usa-original","provider":"AutoControl Global","version":"1.0","type":"link"}