Honeywell CC-TAIX11 Experion Analog Input IOTA Module
Manufacturer: Honeywell
-
Part Number: CC-TAIX11 51308365-175
Condition:New with Original Package
Product Type: Analog Input Modules
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Honeywell CC-TAIX11 Experion IOTA Module
Configured for high-reliability data acquisition in Honeywell distributed control systems, the Honeywell CC-TAIX11 (CC-TAIX11 Redundant Analog Input IOTA) provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | CC-TAIX11 (Part Number 51308365-175) |
| Brand | Honeywell |
| Origin | United States |
| Weight | 0.38 kg |
| Dimensions | 29.4 cm x 12.0 cm x 7.0 cm |
| Operating Temp | -40 to +70 deg C |
| Power Consumption | 10 W |
| Module Type | Redundant Analog Input IOTA Module |
| Number of Channels | 16 analog inputs |
| Input Types | Voltage and Current |
| Voltage Input Range | -10 V to +10 V or 0-10 V |
| Current Input Range | 4-20 mA |
| Resolution | 16-bit A/D conversion |
| Accuracy | +/-0.2% of full scale |
| Response Time | <=2 ms |
| Isolation | 500 V isolation (channel-to-system) |
| Operating Voltage | 12-24 VDC |
| Humidity | 0-95% non-condensing |
| Mounting | DIN-rail mounted |
Process Control & DCS Instrumentation Properties
Operating within the Honeywell Experion PKS framework, this component integrates a dual-slot redundant architecture to maintain uninterrupted process loop data streaming to the C300 controller base. The physical layer provides 500 V galvanic isolation between field loops and internal system electronics, suppressing electrical transients and field noise. The 16-bit analog-to-digital processing layer translates continuous 4-20 mA HART loop protocol signatures and multi-range voltage loops within a deterministic response time of less than 2 ms, preserving channel-to-channel signal separation across high-density field links.
Frequently Asked Questions
Q: How does the CC-TAIX11 IOTA handle a module failure within a redundant configuration?
A: The hardware architecture employs a bumpless transfer design. If the primary analog input module experiences a fault, the secondary module immediately assumes signal processing tasks without interrupting the 12-24 VDC loop circuit or losing data packets.
Q: What input signals are natively supported by the 16 available channels?
A: Each channel accepts standard voltage inputs (-10 V to +10 V or 0-10 V) and current inputs (4-20 mA), making it compatible with a broad range of field transmitters.
Q: Can this termination assembly be installed in unconditioned field enclosures?
A: Yes. The board is specified to operate within an expanded thermal boundary from -40 to +70 deg C, allowing installation in standard external marshalling panels.
Field Installation Guidelines
Affix the CC-TAIX11 IOTA module vertically or horizontally onto an electrically grounded standard DIN rail. Ensure all 12-24 VDC system power feeds are isolated before attaching any underlying electronic module hardware to the interface pins. Terminate field instrumentation lines using the screw terminals, ensuring all 4-20 mA and multi-voltage connections use shielded twisted-pair cables. Terminate the overall cable shields at a single point on the enclosure instrument ground bus bar to optimize the 500 V galvanic isolation barriers and prevent ambient electrical noise from interfering with the 16-bit ADC tracking. Maintain distinct separation between these signal tracks and any high-current AC supply routing inside the cabinet.