{"product_id":"honeywell-cc-taix61-series-8-redundant-analog-input-module","title":"Honeywell CC-TAIX61 Series 8 Redundant Analog Input Module","description":"\u003ch2\u003eHoneywell CC-TAIX61 Series 8 Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAIX61\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TAIX61\u003c\/strong\u003e Redundant Analog Input IOTA, operates as a dedicated hardware component for isolated analog signal acquisition within Experion PKS, C300, and TPS\/TDC 3000 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAIX61 (Part Number 51307077-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e267 x 178 x 52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRedundant Analog Input IOTA (Series 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-20 mA, 0-10 V, +\/-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% to +\/-0.2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 250 ohm (current), \u0026gt; 1 M ohm (voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2500 Vrms channel-to-backplane galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 50 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eG3 conformal coating (corrosion-resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Properties\u003c\/h3\u003e\n\u003cp\u003eOperating within the Honeywell Experion PKS architecture, this execution unit integrates 2500 Vrms channel-to-backplane galvanic isolation parameters to suppress field ground loops and protect system backplane processing layers. The component digitizes incoming signals through high-accuracy 16-bit converters, maintaining field compatibility with 4-20 mA HART loop protocol transmitters as well as multiple voltage levels (+\/-10 V and 0-10 V). It supports 1:1 redundant configurations on specialized Input Output Termination Assemblies (IOTA), providing deterministic scanning across all 16 channels within a maximum window of 50 ms per channel.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-TAIX61 support online module replacement during active process operations?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware fully supports hot-swap operations, allowing a faulty analog input module to be removed and replaced without interrupting field loop tracking or dropping system backplane power.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental classification does the module circuit board carry?\u003c\/p\u003e\n\u003cp\u003eA: The board features standard factory-applied G3 conformal coating, which matches harsh industrial environments by preventing premature oxidation and corrosion from ambient humidity and chemical contaminants.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle a field wire break or signal drop below 4 mA?\u003c\/p\u003e\n\u003cp\u003eA: The internal diagnostics perform automatic open-circuit and under-range\/over-range tracking, sending fault registers to the C300 controller baseplate to block invalid data transmission.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the Series 8 IOTA baseplate assembly directly to a clean, grounded standard DIN rail within the instrument termination enclosure. Before fitting the CC-TAIX61 hardware module into its active termination position, confirm that the 24 VDC system power rail matches nominal tracking values. Terminate all multi-range voltage loops and 4-20 mA input cables at the screw terminal arrays using shielded twisted-pair conductors. Bond all cable shields to the designated instrument ground bus bar inside the enclosure at a single termination point; do not allow dual-end shield paths to prevent ground currents from interfering with the 16-bit analog translation phase.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44288768770147,"sku":null,"price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/370._d088dd6e-2b00-4eb6-b654-04f93147309e.jpg?v=1782282361","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-cc-taix61-series-8-redundant-analog-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}