{"product_id":"honeywell-dc-tdil11-series-c-digital-input-module","title":"Honeywell DC-TDIL11 Series C Digital Input Module","description":"\u003ch2\u003eHoneywell DC-TDIL11 Series C Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed signal acquisition in Honeywell Series C control systems, the \u003cstrong\u003eHoneywell DC-TDIL11\u003c\/strong\u003e (\u003cstrong\u003eDC-TDIL11\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution. The hardware reads binary states from designated field apparatuses, converting incoming voltage levels into system-compatible logic bits across internal backplane registers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDC-TDIL11 (Alternate Part Number: CC-TDIL11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 cm x 12.7 cm x 19.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial Grade Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eCurrent Consumption: 0.190 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 digital input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 millisecond\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V between channels and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL508, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation Parameters\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates precise galvanic separation components to isolate the internal processing logic from external field anomalies. With a rated 1500 V channel-to-system isolation boundary, the hardware suppresses common-mode voltage surges and ground loops. This architecture ensures that field-side electrical interference does not degrade data integrity within the concurrent 16-channel processing matrix.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle backplane current loads during simultaneous 16-channel activation?\u003c\/p\u003e\n\u003cp\u003eA: The module maintains a maximum continuous current consumption of 0.190 A from the backplane supply. The internal bus power tracking remains stable even when all 16 channels register concurrent high-state 24 VDC inputs under minimum latency conditions.\u003c\/p\u003e\n\u003cp\u003eQ: What are the latency limits during redundant switchover execution within Series C systems?\u003c\/p\u003e\n\u003cp\u003eA: The hardware supports redundant chassis configurations where a secondary pair takes over communication loops. Because the physical channel response time is less than 1 millisecond, the digital state table transfers across the redundant bus plane without losing track of input transition events.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Attachment and Pin Preservation:\u003c\/strong\u003e Insert the module vertically into the allocated Series C slot guide rails. Push the assembly backward firmly until the rear connector seats into the backplane, then lock the mechanical fasteners to maintain steady contact pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Ground Connection:\u003c\/strong\u003e Connect all instrument cable shields to a unified ground bar inside the marshaling cabinet. Keep all 24 VDC digital input signal lines separated from high-voltage AC electrical lines to eliminate inductive noise coupling on the signal wires.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring and Inspection:\u003c\/strong\u003e Strip the field wires to the prescribed length before locking them into the terminal block assembly. Perform routine pull tests to verify that no loose wire strands bridge adjacent channels, maintaining the physical integrity of the 1500 V isolation barrier.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43794785927267,"sku":"DC-TDIL11","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/474_d841a9bf-181c-466e-8df3-03e975830f61.jpg?v=1761544220","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-dc-tdil11-series-c-digital-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}