{"product_id":"honeywell-experion-pks-8c-tdoda1-series-8-32-channel-do-module","title":"Honeywell Experion PKS 8C-TDODA1 Series 8 32-Channel DO Module","description":"\u003ch2\u003eHoneywell 8C-TDODA1 Series 8 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-TDODA1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8C-TDODA1\u003c\/strong\u003e Series 8 Digital Output Module, operates as a dedicated hardware component for discrete command execution within Experion LX and PKS platforms. Configured to manage 32 sourcing digital output points, the hardware switches independent 24 VDC control loops based on deterministic program scans from the host controller architecture. The module routes discrete data frames to field-mounted instrumentation while isolating core backplane logic from external wiring faults across the system network.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TDODA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact Series 8 I\/O form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via system baseplate bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 sourcing points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Current Rating\u003c\/td\u003e\n\u003ctd\u003e105 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eField-isolated outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eCompression terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFail-Safe Options\u003c\/td\u003e\n\u003ctd\u003eConfigurable FAILOPT per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 percent to 95 percent non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation\u003c\/h3\u003e\n\u003cp\u003eThe electrical topology of the circuit assembly incorporates channel-to-channel isolation parameters alongside a conformal-coated design to intercept field-induced voltage surges before they propagate to the core processor logic. The 32 output driver stages conform to standard 24 VDC sourcing control loop distributions, regulating load current delivery up to 105 mA per channel for external relays and solenoids. The firmware execution pipeline accommodates independent channel configuration via the FAILOPT parameter matrix, forcing the discrete loops into predefined safe hold or shutdown values during backplane bus communication timeouts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 8C-TDODA1 hardware execute the fail-safe response upon a total loss of baseplate communication?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on the per-channel FAILOPT software register configuration. Upon detection of a backplane communication link interruption, the internal logic automatically forces each of the 32 discrete output circuits to either freeze at the last valid state or drop to a zero-voltage safe state.\u003c\/p\u003e\n\u003cp\u003eQ: Can the sourcing output channels directly drive high-current AC inductive contactor coils?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal semiconductor switching elements are rated exclusively for DC source operations up to a maximum load boundary of 30 VDC. Interfacing the card with AC voltage profiles prevents the internal gates from switching off and causes immediate thermal degradation.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module housing include hardware status indicators for individual channel monitoring?\u003c\/p\u003e\n\u003cp\u003eA: The module front panel integrates discrete LED matrix indicators that mirror the state of the internal output registers, allowing field operators to verify mechanical channel activation against controller logic commands.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module assembly onto the matching Series 8 I\/O baseplate component, confirming that the mechanical alignment alignment keys engage fully before driving the retention screws down. Ensure the enclosure provides sufficient clear boundaries to maintain surrounding air temperatures within the -20 to +60 deg C operational threshold.\u003c\/p\u003e\n\u003cp\u003eStatic fields compromise solid-state components. Field engineers must wear a verified ESD grounding strap or connect to an earth-grounded terminal pad before touching the terminal connectors or extracting the module.\u003c\/p\u003e\n\u003cp\u003eStrip all field terminal connections to the specified conductor length, inserting the wires completely into the compression blocks before torquing the clamping hardware. Route the 24 VDC discrete wiring lines through dedicated wire duct paths away from three-phase AC power lines to block electromagnetic noise transfer across the field-isolated channels.\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":43867257962595,"sku":"8C-TD0DA1","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/356.1_3fe79d67-739b-448f-bba2-12dd73ba1bdd.jpg?v=1764666410","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-experion-pks-8c-tdoda1-series-8-32-channel-do-module","provider":"AutoControl Global","version":"1.0","type":"link"}