{"product_id":"honeywell-fc-tdol-0724p-safety-manager-output-assembly","title":"Honeywell FC-TDOL-0724P Safety Manager Output Assembly","description":"\u003ch2\u003eHoneywell FC-TDOL-0724 P V1.0 Digital Output FTA\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TDOL-0724 P V1.0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-TDOL-0724P\u003c\/strong\u003e Line-Monitored Digital Output Field Termination Assembly (FTA), operates as a dedicated hardware component for relay contact switching and field wiring supervision within Honeywell Safety Manager systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TDOL-0724 P V1.0 \/ FC-TDOL-0724P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e24 cm x 10.8 cm x 8.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal supply (18 to 31.2 VDC tolerance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e7 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003e2 A slow-acting fuse per channel (5 x 20 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Field Load\u003c\/td\u003e\n\u003ctd\u003e50 W per channel (Resistive and inductive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Monitoring\u003c\/td\u003e\n\u003ctd\u003eOpen-circuit and short-circuit fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eSDO-0824 Output Module \/ SDI-1624 Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN EN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eConformal-coated circuit board assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Loop Integrity \u0026amp; Galvanic Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eEngineers integrate the assembly into Safety Manager networks requiring high integrity field loop execution. High-density circuitry utilizes galvanic channel isolation to block common-mode voltage surges and suppress field crosstalk across adjacent channels. Built-in line monitoring continuously verifies field circuit integrity, detecting open-circuit wiring and short-circuit faults whether channels sit energized or de-energized. Internal diagnostic pathways report fault conditions directly back to the Safety Manager I\/O interface without interrupting system loop power execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does line monitoring operate when the output contact is de-energized?\u003c\/p\u003e\n\u003cp\u003eA: The board applies a low-level diagnostic current across the field loop, measuring circuit impedance to detect open circuits or shorted wiring without tripping downstream field devices.\u003c\/p\u003e\n\u003cp\u003eQ: What fuse rating protects individual output channels?\u003c\/p\u003e\n\u003cp\u003eA: Each channel contains a dedicated 2 A slow-acting fuse measuring 5 x 20 mm to protect output switching relays against overcurrent conditions caused by field short circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module on standard DIN EN rail inside clean, enclosure-protected industrial environments. Maintain a minimum 50 mm clearance above and below the module to allow adequate thermal convection across conformal-coated components. Connect incoming system power cables to the 2-pole main power terminal, ensuring proper line polarity. Wire field devices directly to the seven-pair screw terminals, torquing screw connectors to 0.5 Nm. Ground all field cable shields at the enclosure entry point via a single earth bus to eliminate ground loop currents.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67741136879715,"sku":"FC-TDOL-0724P V1.0","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/652_4ebfae3f-070f-476c-9b73-8a155b1f9403.jpg?v=1792375778","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-fc-tdol-0724p-safety-manager-output-assembly","provider":"AutoControl Global","version":"1.0","type":"link"}