Honeywell FC1000A1001 Burner Control with Analog Output
Manufacturer: Honeywell
-
Part Number: FC1000A1001
Condition:New with Original Package
Product Type: Flame Controllers
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Product Overview
The Honeywell FC1000A1001 (FC1000A 1001) serves as a high-precision flame burning controller specifically engineered for the supervision of multi-burner industrial kilns, metallurgical furnaces, and complex chemical heating systems. This 100% brand new, original unit provides critical combustion safety by interpreting signals from either Ultraviolet (UV) sensors or Ionization probes. It converts these signals into actionable digital and analog data, ensuring the system maintains a safe burning state. By offering a rapid flame failure response time of less than 2 seconds, the FC1000A1001 prevents hazardous fuel accumulation, acting as a definitive safeguard for high-capacity industrial thermal assets.
Technical Specifications
The FC1000A1001 integrates seamlessly into existing control panels via its plug-in base architecture.
| Specification | Technical Data |
| Detection Method | Ultraviolet (UV) or Ionization Probe |
| Input Power Supply | 220 VAC ±10%, 50/60 Hz |
| Power Consumption | 5 W maximum |
| Response Time | < 2 seconds (Flame failure detection) |
| Failure Threshold | < 1.5 VDC sustained for > 2 seconds |
| Digital Outputs | 2 x Dry contact outputs (Flame status) |
| Analog Output | 0–5 VDC or 4–20 mA (Optional) |
| Contact Rating | 2 A resistive @ 220 VAC |
| Local Indicators | Green (Power), Red (Flame presence) |
| Protection Class | IP40 |
| Operating Range | 0 to 60 deg C |
| Installation | Panel-mounted plug-in base |
Engineering Advantages
The Honeywell FC1000A1001 addresses common combustion challenges through advanced signal processing:
-
Dual-Detection Flexibility: This controller allows engineers to toggle between UV and Ionization detection without replacing the entire unit. This versatility simplifies spare parts management for facilities utilizing different burner types.
-
Rapid Safety Interlocking: The sub-2-second response time ensures that the fuel valve closes nearly instantaneously upon flame loss. This rapid action protects against explosive gas build-up in large-volume furnace chambers.
-
Signal Precision: Unlike basic detectors, the FC1000A1001 provides an optional 4–20 mA analog output. This allows operators to monitor flame intensity in real-time through a DCS or PLC, enabling predictive maintenance before a nuisance shutdown occurs.
-
Simplified Troubleshooting: High-visibility LED indicators on the front panel provide immediate status updates. The dry contact outputs allow for easy integration into emergency shutdown (ESD) loops or local alarm circuits.
FAQs
-
Does the FC1000A1001 require a specific mounting base?
Yes, the unit utilizes a standard plug-in base for panel installation. This design allows for "hot-swapping" the controller during maintenance without disconnecting the field wiring from the base terminals.
-
Can I use both UV and Ionization detection simultaneously?
No, while the controller supports both methods, you must configure it to operate with one specific probe type at a time based on your burner’s physical characteristics and fuel type.
-
What happens if the flame signal drops below 1.5 VDC?
If the signal remains below the 1.5 VDC threshold for more than 2 seconds, the controller triggers a failure state, de-energizing the flame status contacts to initiate a safety shutdown.
-
Is this unit compatible with 110 VAC systems?
The standard FC1000A1001 operates on 220 VAC. Always verify your local power supply specifications before energizing the module to prevent internal component damage.