Honeywell FC1000A1001 Burner Control with Analog Output
Honeywell FC1000A1001 Burner Control with Analog Output
Honeywell FC1000A1001 Burner Control with Analog Output
/ 3

Honeywell FC1000A1001 Burner Control with Analog Output

  • Manufacturer: Honeywell

  • Part Number: FC1000A1001

  • Condition:New with Original Package

  • Product Type: Flame Controllers

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The Honeywell FC1000A1001 (FC1000A 1001) serves as a high-precision flame burning controller specifically engineered for the supervision of multi-burner industrial kilns, metallurgical furnaces, and complex chemical heating systems. This 100% brand new, original unit provides critical combustion safety by interpreting signals from either Ultraviolet (UV) sensors or Ionization probes. It converts these signals into actionable digital and analog data, ensuring the system maintains a safe burning state. By offering a rapid flame failure response time of less than 2 seconds, the FC1000A1001 prevents hazardous fuel accumulation, acting as a definitive safeguard for high-capacity industrial thermal assets.

Technical Specifications

The FC1000A1001 integrates seamlessly into existing control panels via its plug-in base architecture.

Specification Technical Data
Detection Method Ultraviolet (UV) or Ionization Probe
Input Power Supply 220 VAC ±10%, 50/60 Hz
Power Consumption 5 W maximum
Response Time < 2 seconds (Flame failure detection)
Failure Threshold < 1.5 VDC sustained for > 2 seconds
Digital Outputs 2 x Dry contact outputs (Flame status)
Analog Output 0–5 VDC or 4–20 mA (Optional)
Contact Rating 2 A resistive @ 220 VAC
Local Indicators Green (Power), Red (Flame presence)
Protection Class IP40
Operating Range 0 to 60 deg C
Installation Panel-mounted plug-in base

Engineering Advantages

The Honeywell FC1000A1001 addresses common combustion challenges through advanced signal processing:

  • Dual-Detection Flexibility: This controller allows engineers to toggle between UV and Ionization detection without replacing the entire unit. This versatility simplifies spare parts management for facilities utilizing different burner types.

  • Rapid Safety Interlocking: The sub-2-second response time ensures that the fuel valve closes nearly instantaneously upon flame loss. This rapid action protects against explosive gas build-up in large-volume furnace chambers.

  • Signal Precision: Unlike basic detectors, the FC1000A1001 provides an optional 4–20 mA analog output. This allows operators to monitor flame intensity in real-time through a DCS or PLC, enabling predictive maintenance before a nuisance shutdown occurs.

  • Simplified Troubleshooting: High-visibility LED indicators on the front panel provide immediate status updates. The dry contact outputs allow for easy integration into emergency shutdown (ESD) loops or local alarm circuits.

FAQs

  • Does the FC1000A1001 require a specific mounting base?

    Yes, the unit utilizes a standard plug-in base for panel installation. This design allows for "hot-swapping" the controller during maintenance without disconnecting the field wiring from the base terminals.

  • Can I use both UV and Ionization detection simultaneously?

    No, while the controller supports both methods, you must configure it to operate with one specific probe type at a time based on your burner’s physical characteristics and fuel type.

  • What happens if the flame signal drops below 1.5 VDC?

    If the signal remains below the 1.5 VDC threshold for more than 2 seconds, the controller triggers a failure state, de-energizing the flame status contacts to initiate a safety shutdown.

  • Is this unit compatible with 110 VAC systems?

    The standard FC1000A1001 operates on 220 VAC. Always verify your local power supply specifications before energizing the module to prevent internal component damage.