{"product_id":"honeywell-fc1000a1001-burner-control-with-analog-output","title":"Honeywell FC1000A1001 Burner Control with Analog Output","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell FC1000A1001 (FC1000A 1001) serves as a high-precision flame burning controller specifically engineered for the supervision of multi-burner industrial kilns, metallurgical furnaces, and complex chemical heating systems. This 100% brand new, original unit provides critical combustion safety by interpreting signals from either Ultraviolet (UV) sensors or Ionization probes. It converts these signals into actionable digital and analog data, ensuring the system maintains a safe burning state. By offering a rapid flame failure response time of less than 2 seconds, the FC1000A1001 prevents hazardous fuel accumulation, acting as a definitive safeguard for high-capacity industrial thermal assets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe FC1000A1001 integrates seamlessly into existing control panels via its plug-in base architecture.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUltraviolet (UV) or Ionization Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220 VAC ±10%, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 W maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 2 seconds (Flame failure detection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFailure Threshold\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 1.5 VDC sustained for \u0026gt; 2 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x Dry contact outputs (Flame status)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–5 VDC or 4–20 mA (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A resistive @ 220 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreen (Power), Red (Flame presence)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP40\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel-mounted plug-in base\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell FC1000A1001 addresses common combustion challenges through advanced signal processing:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Detection Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis controller allows engineers to toggle between UV and Ionization detection without replacing the entire unit. This versatility simplifies spare parts management for facilities utilizing different burner types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Safety Interlocking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe sub-2-second response time ensures that the fuel valve closes nearly instantaneously upon flame loss. This rapid action protects against explosive gas build-up in large-volume furnace chambers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike basic detectors, the FC1000A1001 provides an optional 4–20 mA analog output. This allows operators to monitor flame intensity in real-time through a DCS or PLC, enabling predictive maintenance before a nuisance shutdown occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-visibility LED indicators on the front panel provide immediate status updates. The dry contact outputs allow for easy integration into emergency shutdown (ESD) loops or local alarm circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the FC1000A1001 require a specific mounting base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the unit utilizes a standard plug-in base for panel installation. This design allows for \"hot-swapping\" the controller during maintenance without disconnecting the field wiring from the base terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use both UV and Ionization detection simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, while the controller supports both methods, you must configure it to operate with one specific probe type at a time based on your burner’s physical characteristics and fuel type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the flame signal drops below 1.5 VDC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the signal remains below the 1.5 VDC threshold for more than 2 seconds, the controller triggers a failure state, de-energizing the flame status contacts to initiate a safety shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with 110 VAC systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standard FC1000A1001 operates on 220 VAC. Always verify your local power supply specifications before energizing the module to prevent internal component damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43810855354467,"sku":"FC1000A1001","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/24_cbb11098-4666-44a3-8722-78706d979c3a.jpg?v=1776413652","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-fc1000a1001-burner-control-with-analog-output","provider":"AutoControl Global","version":"1.0","type":"link"}