{"product_id":"honeywell-fs-qpp-0002-quad-processor-logic-card-original","title":"Honeywell FS-QPP-0002 | Quad Processor Logic Card Original","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS-QPP-0002 (Model: FS-QPP-0002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Quad Processor Platform (QPP) module engineered for Honeywell Safety Manager and Fail Safe Control (FSC) systems. As a core logic-solving engine, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS-QPP-0002 (Order Number: FS-QPP-0002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the computational power necessary for real-time safety monitoring, complex logic execution, and rapid fault detection in Safety Instrumented Systems (SIS).\u003c\/p\u003e\n\u003cp\u003eThis module utilizes a multi-processor, fault-tolerant architecture to ensure maximum system availability. By employing a \"quad\" processing approach, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS-QPP-0002 (Part Number: FS-QPP-0002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eperforms continuous hardware-level comparisons of processing results, ensuring that any internal discrepancy is immediately identified and mitigated. This level of deterministic performance is critical for mission-critical automation in oil and gas refineries, chemical processing plants, and power generation facilities where functional safety is the highest priority.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS-QPP-0002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to meet the rigorous demands of SIL-rated safety loops.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS-QPP-0002\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Quad Processor Platform (QPP) Logic Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Application\u003c\/strong\u003e: Honeywell Safety Manager \/ FSC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessing Architecture\u003c\/strong\u003e: Quad-processor, hardware fault-tolerant (HFT) design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: High-speed safety logic solving and system coordination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e: Supports redundant pair configurations for high availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e: Redundant system bus and high-speed backplane interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Protection\u003c\/strong\u003e: Integrated ECC (Error Correction Code) for data integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Coverage\u003c\/strong\u003e: \u0026gt;99% via built-in self-tests and hardware watchdogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: Supplied via system chassis (typically 5V DC internal rails)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 1.2A at 5V DC (Load dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Front-loading in dedicated CPU slots of the Safety Manager chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20°C to +60°C (-4°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e: SIL 3 (IEC 61508), CE, UL, TUV, and FM Global\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44029174677603,"sku":"FS-QPP-0002","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/121._0deb67ae-5845-4492-b74a-4cdbdab37a9d.jpg?v=1772260147","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-fs-qpp-0002-quad-processor-logic-card-original","provider":"AutoControl Global","version":"1.0","type":"link"}