Honeywell FSC Digital Output 10216/2/1 | TÜV Certified 4-Ch
Honeywell FSC Digital Output 10216/2/1 | TÜV Certified 4-Ch
Honeywell FSC Digital Output 10216/2/1 | TÜV Certified 4-Ch
/ 3

Honeywell FSC Digital Output 10216/2/1 | TÜV Certified 4-Ch

  • Manufacturer: Honeywell

  • Part Number: 10216/2/1

  • Condition:New with Original Package

  • Product Type: Digital Output Module

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Honeywell 10216/2/1 FSC Fail-Safe 4-Channel Digital Output Module

Product Description

The 10216/2/1 (10216/2/1) is a high-integrity, fail-safe digital output module designed for the Honeywell Fail Safe Control (FSC) system. This loop-monitored module is specifically engineered for critical 24 Vdc safety applications, offering four independent output channels with a robust 1 A current capacity per channel. It is a fundamental component for safety-instrumented systems (SIS) that require deterministic de-energization during fault conditions.

The 10216/2/1 (10216/2/1) features integrated overload detection and short-circuit protection, ensuring the longevity of both the module and connected field devices. With its loop-monitoring capabilities, the module can detect field-side issues such as open circuits or shorted lines, reporting diagnostics directly to the FSC processor. This module is globally certified by TÜV, CE, and UL for use in mission-critical environments like Emergency Shutdown (ESD) and Fire and Gas (F&G) systems.

Detailed Technical Specifications

The following technical parameters outline the electrical and physical characteristics of the 10216/2/1:

  • Manufacturer: Honeywell

  • Model Number: 10216/2/1

  • Product Type: Fail-Safe Loop-Monitored Digital Output Module

  • Number of Channels: 4 Channels

  • Output Type: 24 Vdc Solid-state source (Short-circuit proof)

  • Maximum Current per Channel: 1 A

  • Maximum Total Module Load: 3.6 A

  • Maximum Load Inductance: 0.5 H

  • Maximum Load Capacity: 1 µF

  • Voltage Drop at 1 A: < 1.3 V

  • Current Sense Voltage Drop: < 1 V at 1 A

  • Off-State Leakage Current: < 0.1 mA

  • Overload Detection Threshold: > 10 Ohm

  • Power Requirements (5 Vdc): 15 mA

  • Power Requirements (Internal 24 Vdc): 50 mA

  • Power Requirements (External 24 Vdc): 15 mA (at idle)

  • Watchdog (WDG) Input Current: 4 mA

  • Space Requirements: 4 TE width, 3 HE height (4 HP, 3U)

  • Mechanical Safety Coding: Holes A13, C9 (Rack Pins A13, C9)

  • Safety Approvals: CE, TÜV, UL

  • Software Requirement: Version ≥ 3.00