{"product_id":"honeywell-mc-pdoy22-experion-pks-series-c-digital-output-module","title":"Honeywell MC-PDOY22 Experion PKS Series C Digital Output Module","description":"\u003ch2\u003eHoneywell MC-PDOY22 Experion PKS Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-PDOY22\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMC-PDOY22\u003c\/strong\u003e Digital Output Control Module, operates as a dedicated hardware component for discrete signal switching within Honeywell Experion PKS Series C I\/O, TPS, and TDC 3000 systems platforms. Configured for converting controller logic into precise ON\/OFF signals, the \u003cstrong\u003eHoneywell MC-PDOY22\u003c\/strong\u003e (\u003cstrong\u003eMC-PDOY22\u003c\/strong\u003e Digital Output Control Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-PDOY22 (Part Number: 80363975-150)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFactory standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e267 x 178 x 51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDerived from backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 - 32 digital output channels (configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003eUp to 1 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSolid-state transistor outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Strength\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-system galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eOver-current protection, surge suppression, short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% - 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL508, CSA, TUV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture incorporates solid-state transistor outputs utilizing channel-to-channel isolation to decouple each electrical field loop from parallel processing nodes. This galvanic isolation prevents transient surge migration and maintains structural integrity during high-frequency inductive switching events. Field loop telemetry works independently of the 4-20 mA HART loop protocol baselines established within adjacent analog control slots, isolating digital switching noise from low-level measuring elements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the channel-to-channel isolation architecture protect the host controller backplane?\u003c\/p\u003e\n\u003cp\u003eA: The galvanic isolation barrier electrically separates individual output loops, ensuring that a field-side short circuit or over-voltage fault on one channel cannot propagate to adjacent channels or corrupt the system logic rails.\u003c\/p\u003e\n\u003cp\u003eQ: What happens if a field device exceeds the 1 A current limit on a specific output channel?\u003c\/p\u003e\n\u003cp\u003eA: Internal over-current and short-circuit protection components immediately trip the faulted channel to prevent thermal degradation, while onboard diagnostic registers flag the event to the central processor.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module hot-swappable during active control execution?\u003c\/p\u003e\n\u003cp\u003eA: Online replacement must comply strictly with Honeywell rack safety instructions, requiring localized loop bypass configuration within the engineering workstation before pulling the module to prevent unintended process trips.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that all external 24 VDC field power sources are isolated before terminating field wiring plugs to the card interfaces.\u003c\/li\u003e\n\u003cli\u003eUse dedicated static-shielding equipment and a verified grounding wrist strap when mounting or configuring the module chassis.\u003c\/li\u003e\n\u003cli\u003eRoute discrete output conductors away from high-voltage AC motor lines to eliminate inductive cross-talk within the control cabinet routing trays.\u003c\/li\u003e\n\u003cli\u003eEnsure all terminal blocks are seated squarely and the mounting screws are torqued down to maintain proper connection pressure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43866402422883,"sku":"MC-DDOY22","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/130._0f70a5bf-9888-474d-9d76-e112a422003a.jpg?v=1784711943","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-mc-pdoy22-experion-pks-series-c-digital-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}