{"product_id":"honeywell-mu-mc-taox12-51304441-175-analog-output-module","title":"Honeywell MU\/MC-TAOX12 51304441-175 Analog Output Module","description":"\u003ch2\u003eHoneywell MU\/MC-TAOX12 51304441-175 Analog Output Processors\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MU\/MC-TAOX12 51304441-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMU\/MC-TAOX12\u003c\/strong\u003e Analog Output Processors, operates as a dedicated hardware component for converting controller digital commands into high-accuracy analog driving signals within Experion PKS and TPS\/TDC 3000 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU\/MC-TAOX12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (Net) \/ 1.5 kg (Shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Honeywell High-Performance Process Manager (HPM) I\/O module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51304441-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e12 Analog Output Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current loop \/ 0-10 VDC configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of Full Scale at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation (channel-to-channel and channel-to-system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol Execution\u003c\/h3\u003e\n\u003cp\u003eThe MU\/MC-TAOX12 51304441-175 incorporates dedicated digital-to-analog conversion circuits paired with robust output drivers that enforce strict galvanic channel-to-channel isolation. This isolation prevents ground loops and electrical cross-talk across its 12 current loops. Designed to interface seamlessly with modern field instrumentation, the internal current drivers support superimposing digital 4-20 mA HART loop protocol signals without compromising signal integrity or loop update times. Integrated cold junction compensation and precision feedback loops maintain output accuracy within +\/-0.1% of full scale across varying ambient field temperatures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the MU\/MC-TAOX12 support hot-swapping under powered rack conditions?\u003c\/p\u003e\n\u003cp\u003eA: Yes, technicians can hot-swap the module in a powered I\/O rack provided the system is configured in a redundant pair or the associated loop is placed in manual override mode. Observe standard anti-static procedures during insertion to prevent ESD damage to sensitive CMOS circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle output signal states during a loss of controller communication?\u003c\/p\u003e\n\u003cp\u003eA: The module executes a pre-configured fail-safe state. Depending on field parameter settings, each of the 12 analog channels defaults to a hold-last-value state, fails low (0 mA \/ 3.8 mA), or drops to a designated safe value to preserve process containment.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the MU\/MC-TAOX12 51304441-175 securely into the designated I\/O card chassis or DIN-rail carrier frame. Verify that the 24 VDC power supply bus voltage matches system tolerances before applying power. Ensure that all signal cable shields link directly to the cabinet instrumentation earth bus at a single grounding point to avoid circulating earth currents. Maintain separation between signal wires carrying 4-20 mA current and high-voltage AC lines within panel wiring ducts to minimize electromagnetic interference.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44021571092579,"sku":"MU\/MC-TAOX12 51304441-175","price":580.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/81_91587d4a-05ba-4d38-a1fe-59abcc29160a.jpg?v=1771917395","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-mu-mc-taox12-51304441-175-analog-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}