{"product_id":"honeywell-rm7890a1056-relay-module-new-original-stock","title":"Honeywell RM7890A1056 Relay Module | New \u0026 Original Stock","description":"\u003ch2\u003eHoneywell RM7890A1056 7800 Series Relay Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for automatic sequencing, flame supervision, and system status monitoring in Honeywell 7800 Series platforms, the \u003cstrong\u003eHoneywell RM7890A1056\u003c\/strong\u003e (\u003cstrong\u003eRM7890A1056\u003c\/strong\u003e Burner Control Relay Module) provides direct physical\/electrical execution. The microprocessor-based component manages single on\/off gas burner safety logic, regulating start-up preignition interlock sequences, pilot valve gating, and primary fuel safety shutoff valves based on active optical inputs.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRM7890A1056\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.25 kg (2.75 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e127 mm x 127 mm x 127 mm (5.0 in x 5.0 in x 5.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 60 deg C (-40 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced via subbase (120 VAC or 230 VAC configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Architecture\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor-based integrated burner control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Subsystem Type\u003c\/td\u003e\n\u003ctd\u003eGas burners (single burner, on\/off operational profiles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePilot Selection Logic\u003c\/td\u003e\n\u003ctd\u003eSelectable intermittent or interrupted pilot gating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreignition Interlock Input\u003c\/td\u003e\n\u003ctd\u003eHardwired dry-contact interlock loop verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Control Interfaces\u003c\/td\u003e\n\u003ctd\u003eIntegrated Run\/Test toggle switch for interrupted pilot isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlame Failure Response Time\u003c\/td\u003e\n\u003ctd\u003e0.8 to 3.0 seconds typical (determined by nested flame amplifier)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubbase Mounting\u003c\/td\u003e\n\u003ctd\u003ePlug-in mechanical chassis insertion orientation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL recognized, CSA certified, FM approved, CE compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe RM7890A1056 executes synchronous state logic tracking by monitoring hardwired discrete input loops, including the preignition interlock path and air-flow validation switches. While complex distributed nodes utilize the 4-20 mA HART loop protocol for variable process tracking, this discrete burner safeguard enforces dedicated channel-to-channel isolation parameters across its high-voltage output relays. This internal electrical barrier isolates the micro-control logic core from switching noise, reactive inductive kickback from ignition transformers, and line voltage spikes, ensuring that external terminal faults do not bridge the main safety circuits or compromise the fail-safe shutdown sequence.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the physical flame failure response time (FFRT) determined inside this relay module assembly?\u003c\/p\u003e\n\u003cp\u003eA: The baseline FFRT parameters are governed by the specific sub-component plug-in flame amplifier card (ultraviolet, infrared, or flame rectification) inserted into the RM7890A1056 chassis. The module logic processes the raw output from this intermediate amplifier within an operational window ranging from 0.8 to 3.0 seconds maximum before dropping the fuel valve circuit pins.\u003c\/p\u003e\n\u003cp\u003eQ: Can this microprocessor-based module be unseated or replaced while the subbase terminals are energized?\u003c\/p\u003e\n\u003cp\u003eA: No. The line voltage supply driving the terminal subbase must be fully isolated before executing removal or insertion tasks. Live insertion into an energized subbase can induce high-voltage inrush transients across the logic bus pins, creating electrical arcing risks and permanently degrading the solid-state safety gating logic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubbase Interface Alignment\u003c\/strong\u003e: Prior to mounting, verify that all mechanical guidance tabs and rear electrical plug pins align cleanly with the wiring subbase slots. Press the module firmly into place, securing the integral mounting screws to establish low-impedance framing contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterlock Loop Conductor Routing\u003c\/strong\u003e: Route all safety interlock wiring (limits, gas pressure switches, and air proving bails) through dedicated wireways separated from three-phase AC power conduits. Keep all lead runs beneath maximum resistance specifications to prevent voltage sag across the logic sensing loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Plane Integrity\u003c\/strong\u003e: Connect the main subbase chassis ground terminal directly to the enclosure single-point earth ground bar using a low-resistance green copper conductor. A solid ground connection is necessary to avoid signal noise and protect the flame voltage verification circuit from drift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Thermal Boundary Verification\u003c\/strong\u003e: Install the module chassis inside a NEMA-rated or IP-rated protective control panel. Ensure ambient temperatures immediately surrounding the plastic shell stay within the -40 to 60 deg C parameters, avoiding radiant heat transfer from the burner housing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43869081043043,"sku":"RM7890A1056","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/393_7a8772d6-d802-4e55-a2c5-c88b20ff0d15.jpg?v=1764745548","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-rm7890a1056-relay-module-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}