{"product_id":"ic200alg230d-ge-fanuc-versamax-analog-input-module-4-ch-12-bit","title":"IC200ALG230D GE Fanuc VersaMax Analog Input Module 4-CH 12-Bit","description":"\u003ch2\u003eGE IC200ALG230D VersaMax Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog signal measurement and digital data conversion in GE VersaMax PLC platforms, the \u003cstrong\u003eGE IC200ALG230D\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG230\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. Technicians snap this module onto VersaMax I\/O carriers to acquire field voltage and current signals. The hardware converts single-ended field inputs into 12-bit digital values across the backplane without requiring external signal conditioning blocks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG230D (IC200ALG230)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg to 0.54 kg (varies by carrier assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e66.8 x 128 mm (2.63 x 5.04 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e125 mA at 5 VDC (from backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eVersaMax PLC platform \/ I\/O carriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e4 \/ 8 channels (single-ended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003eBipolar \/ Unipolar (0-10 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e0.4 ms to 1.0 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V between field side and logic side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eINT PWR and OK LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eVersaMax DIN-rail snap-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Deterministic Network Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module uses backplane bus communication velocity protocol management to drive deterministic I\/O density scaling across VersaMax sub-racks. Internal logic circuits execute rapid data conversion scans with a 0.4 ms update rate, minimizing signal phase latency in real-time control loops. Optical isolation barriers isolate the internal 5 VDC backplane power rail from field-side electrical surges up to 1500 V. In addition, firmware flash compatibility validation prevents invalid parameter assignments during CPU configuration cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power draw does the IC200ALG230D exert on the VersaMax backplane logic rail?\u003c\/p\u003e\n\u003cp\u003eA: The module draws up to 125 mA at 5 VDC from the backplane power supply.\u003c\/p\u003e\n\u003cp\u003eQ: How do status LEDs indicate power and operational state changes on the module front panel?\u003c\/p\u003e\n\u003cp\u003eA: The INT PWR LED confirms the presence of internal 5 VDC logic power, while the OK LED lights up continuously when the module passes backplane hardware diagnostics.\u003c\/p\u003e\n\u003cp\u003eQ: What signal isolation exists between field input terminals and the CPU backplane?\u003c\/p\u003e\n\u003cp\u003eA: Integrated optical couplers provide 1500 V galvanic isolation between the field-side input circuits and the backplane logic bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTechnicians must snap the module base firmly onto the DIN-rail before seating it into the VersaMax I\/O carrier interface. Tighten all terminal block screws to secure sensor wiring, using single-ended wiring practices for voltage signals. Route analog input cables in dedicated wire ducts separate from high-voltage AC lines to minimize noise pick-up. Terminate overall cable shielding directly to the cabinet ground bar using low-impedance clamps prior to applying power to the PLC system.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44521454272611,"sku":"IC200MDL740L","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/184._0ebf5807-7e59-4afa-b05f-b79b4cbf51b8.jpg?v=1787821102","url":"https:\/\/www.autocontrolglobal.com\/products\/ic200alg230d-ge-fanuc-versamax-analog-input-module-4-ch-12-bit","provider":"AutoControl Global","version":"1.0","type":"link"}