{"product_id":"ic200ebi001-pl-ge-fanuc-versamax-ethernet-network-module","title":"IC200EBI001-PL GE Fanuc VersaMax Ethernet Network Module","description":"\u003ch2\u003eGE Fanuc IC200EBI001-PL VersaMax Ethernet Network Interface Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for industrial Ethernet network bridge execution in VersaMax PLC systems, the \u003cstrong\u003eGE Fanuc IC200EBI001-PL\u003c\/strong\u003e (\u003cstrong\u003eIC200EBI001\u003c\/strong\u003e Ethernet Network Interface Module) provides direct physical\/electrical execution for real-time I\/O telemetry exchange across local control nodes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200EBI001-PL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg (0.31 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e133.4 mm x 69.1 mm x 85.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e175 mA at +5 VDC, 425 mA at +3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eEthernet RJ-45 (10Base-T \/ 100Base-TX auto-negotiation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocols\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, UDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e1024 bytes total (512 bytes input \/ 512 bytes output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Expansion\u003c\/td\u003e\n\u003ctd\u003eUp to 64 I\/O modules across 7 expansion racks (Release 1.01+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe network interface maps local and remote I\/O data arrays across Ethernet networks with minimal network transport latency, processing TCP\/IP and UDP packet streams simultaneously. Integrated logic circuits manage backplane bus communication velocity across up to 7 expansion racks, maintaining cyclic update speeds without dropping I\/O image tables. Furthermore, internal flash memory supports firmware flash compatibility with main VersaMax CPU modules, ensuring continuous diagnostic monitoring, status LED reporting, and uninterrupted backplane communication under high data throughput conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the IC200EBI001-PL handle I\/O rack expansion across local backplane networks?\u003c\/p\u003e\n\u003cp\u003eA: Starting with firmware Release 1.01 or later, the interface module orchestrates process data transfer for up to 64 I\/O modules distributed across 7 expansion racks, mapping 512 input bytes and 512 output bytes directly to the host CPU memory table.\u003c\/p\u003e\n\u003cp\u003eQ: What power rails must the backplane supply to keep the module operational?\u003c\/p\u003e\n\u003cp\u003eA: The backplane power supply must deliver a regulated +5 VDC rail drawing up to 175 mA alongside a +3.3 VDC logic rail drawing up to 425 mA to maintain proper Ethernet transceiver operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the network interface module securely onto a standard 35 mm DIN rail inside an enclosure that maintains ambient operating temperatures between 0 deg C and +60 deg C. Connect Category 5e or higher shielded Ethernet cabling through the RJ-45 connector, keeping network cables physically separated from three-phase AC power wiring and variable frequency drive leads to prevent electromagnetic noise. Field technicians should ground the DIN rail to a central panel earthing bar with a low-impedance copper strap, verify that backplane bus connectors align before snapping expansion racks together, and confirm supply voltage stability before applying system power.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43876765565027,"sku":"IC200EBI001-PL","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/217_28ee3f83-6db3-4d45-98f2-6679ac8fc3a1.jpg?v=1765165989","url":"https:\/\/www.autocontrolglobal.com\/products\/ic200ebi001-pl-ge-fanuc-versamax-ethernet-network-module","provider":"AutoControl Global","version":"1.0","type":"link"}