{"product_id":"ic200mdd844b-ge-versamax-discrete-mixed-i-o-module","title":"IC200MDD844B GE VersaMax Discrete Mixed I\/O Module","description":"\u003ch2\u003eGE Fanuc IC200MDD844B VersaMax Mixed I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDD844B\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDD844\u003c\/strong\u003e Mixed I\/O Module, operates as a dedicated hardware component for localized digital signal processing and field actuator control within GE VersaMax PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDD844B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (2.2 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e95 mm W x 76 mm D x 90 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC external supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated I\/O\u003c\/td\u003e\n\u003ctd\u003e84 total points (48 DC inputs, 36 DC transistor outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC positive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDC transistor outputs (sourcing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point, 2 A per common group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e9 KB user logic memory, 256 bytes registers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eRS-232 (RJ-45 port), SNP\/SNPX, Modbus RTU slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module executes rapid data exchange across the localized backplane bus, driving determinism during high-density I\/O scan intervals. Integrated firmware flash compatibility preserves output state mapping and internal register values when processing 84 discrete channels simultaneously. Furthermore, high I\/O density scaling reduces rack space requirements while maintaining reliable signal throughput between field sensors and the CPU.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum current load permitted on the DC transistor outputs?\u003c\/p\u003e\n\u003cp\u003eA: Each sourcing transistor output point handles a maximum continuous current of 0.5 A at 24 VDC, with a total current limit of 2 A per common group.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication protocols are natively supported on the onboard serial interface?\u003c\/p\u003e\n\u003cp\u003eA: The onboard RJ-45 RS-232 port supports SNP, SNPX, and Modbus RTU slave protocols for direct interface with operator panels and programming software.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFollow these core practices during physical mounting and wiring setup:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMount the module onto a standard 35 mm DIN-rail or secure it to an earthed backpanel using dedicated mounting screws.\u003c\/li\u003e\n\u003cli\u003eRoute 24 VDC discrete sensor and actuator cabling separately from high-voltage AC lines to minimize inductive interference.\u003c\/li\u003e\n\u003cli\u003eConnect signal cable shields directly to the cabinet local earth bus bar using short grounding straps.\u003c\/li\u003e\n\u003cli\u003eVerify that inductive DC loads connected to transistor outputs incorporate flyback diodes to prevent voltage transients from damaging output channels.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44458532044899,"sku":"IC200MDD844B","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/486_4013ac0f-b9c0-4d72-aac5-4295f55c8e2b.jpg?v=1786350885","url":"https:\/\/www.autocontrolglobal.com\/products\/ic200mdd844b-ge-versamax-discrete-mixed-i-o-module","provider":"AutoControl Global","version":"1.0","type":"link"}