{"product_id":"ic200mdl632-ge-versamax-125-vdc-16-point-discrete-input-module","title":"IC200MDL632 GE VersaMax 125 VDC 16 Point Discrete Input Module","description":"\u003ch2\u003eGE IC200MDL632 VersaMax Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IC200MDL632\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDL632\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for high-voltage DC field status monitoring and signal isolation within GE VersaMax PLC platforms. Field engineers seat the module onto a standard VersaMax carrier terminal base where it converts 16 individually isolated 125 VDC discrete inputs into internal logic state data. High-speed optical isolators process incoming voltage levels while dedicated status LEDs provide real-time visual channel diagnostics across the module front panel.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (GE Fanuc \/ Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Standard Industrial Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg (0.63 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e66.8 x 128 mm (2.63 x 5.04 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA maximum (from 5 VDC backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channel Count\u003c\/td\u003e\n\u003ctd\u003e16 points (Individually isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e125 VDC (0 to 150 VDC input range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Logic Support\u003c\/td\u003e\n\u003ctd\u003ePositive and Negative logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e74 k-ohms typical at 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse \/ Filter Delay\u003c\/td\u003e\n\u003ctd\u003e0.5 ms maximum response; configurable 0 ms, 1.0 ms, 7.0 ms filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous, 1500 VAC for 1 min (Channel-to-channel and channel-to-backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and System Integration\u003c\/h3\u003e\n\u003cp\u003eThe discrete input card transfers channel state transitions directly onto the internal rack bus, preserving backplane bus communication velocity across expanded VersaMax sub-racks. Dedicated optical isolation hardware shields processing nodes from high-voltage field spikes, which prevents communication disruptions over connected EtherNet\/IP and Profinet deterministic networks. Full firmware flash compatibility across attached VersaMax CPU modules ensures rapid backplane synchronization and eliminates scan timing errors during high I\/O density scaling transitions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How do technical personnel change the input hardware filter delays on the IC200MDL632 module?\u003c\/p\u003e\n\u003cp\u003eA: Engineers adjust the software configurable filter delay settings (0 ms, 1.0 ms, or 7.0 ms) inside the VersaMax programming software to eliminate electrical contact bounce and field line noise.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation boundaries protect connected CPU racks from field-side voltage surges?\u003c\/p\u003e\n\u003cp\u003eA: Individual optical barriers provide 250 VAC continuous and 1500 VAC 1-minute surge withstand ratings between channel groups, between individual channels, and between field wiring and the backplane logic ground.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IC200MDL632 module draw operating power for field contacts from the VersaMax backplane?\u003c\/p\u003e\n\u003cp\u003eA: The module draws up to 80 mA from the 5 VDC backplane rail solely to power internal processing logic and LED indicators, requiring external 125 VDC power sources to drive the field input loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFollow these sequential steps during cabinet assembly and wiring setup:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect main power feeds supplying the VersaMax rack and lock out field input voltage loops prior to installation.\u003c\/li\u003e\n\u003cli\u003eAlign the module edge connector over the designated slot on the VersaMax carrier base and push downward until the locking latches snap shut.\u003c\/li\u003e\n\u003cli\u003eConnect 125 VDC input signal conductors to the removable terminal block, verifying polarity alignments for positive or negative logic field circuits.\u003c\/li\u003e\n\u003cli\u003eRoute high-voltage 125 VDC input signal cables in separate wiring trunks away from sensitive low-voltage analog or communication lines.\u003c\/li\u003e\n\u003cli\u003eTerminate field cable drain shields directly at the cabinet ground rail via low-impedance ground straps, then apply logic power to verify the module OK LED status.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44521290760291,"sku":"IC200MDL632","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/180_e70daa55-727f-47a6-91a6-7e340fe46674.jpg?v=1787817062","url":"https:\/\/www.autocontrolglobal.com\/products\/ic200mdl632-ge-versamax-125-vdc-16-point-discrete-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}