{"product_id":"ic200mdl750k-ge-versamax-32-point-24-vdc-output-module","title":"IC200MDL750K GE VersaMax 32 Point 24 VDC Output Module","description":"\u003ch2\u003eGE IC200MDL750K VersaMax Discrete Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDL750K\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDL750\u003c\/strong\u003e Discrete Output Module, operates as a dedicated hardware component for switching field actuators and loads within VersaMax I\/O platforms. The module provides 32 sourcing-type channels arranged in two isolated groups of 16 points. Internal switching transistors source power from external 12\/24 VDC field supplies directly to connected indicators, relays, and solenoids.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL750K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 30 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e90 mA backplane current draw at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Density\u003c\/td\u003e\n\u003ctd\u003e32 channels (2 groups of 16 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10.2 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A for 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn\/Off Response Time\u003c\/td\u003e\n\u003ctd\u003eON: 0.2 ms; OFF: 1.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous group-to-group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eInternal optical isolators separate backplane communication processing circuits from field-side voltage transients up to 1500 VAC for 1 minute. The module receives digital state frames from the primary rack controller, updating all 32 channel output transistors while maintaining deterministic bus communication velocity across adjacent expansion bases. Onboard logic circuits execute firmware flash compatibility checks upon backplane power initialization to verify module configuration parameters before enabling output driver stages.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module contain internal current fuses to protect output transistors from field short circuits?\u003c\/p\u003e\n\u003cp\u003eA: The module does not feature internal field fuses. System designers must install external fast-acting fuses or current-limiting devices on individual field output circuits to protect internal switching transistors against direct short circuits and overcurrent faults.\u003c\/p\u003e\n\u003cp\u003eQ: How do inductive field loads affect the switching lifetime of the output channels?\u003c\/p\u003e\n\u003cp\u003eA: Switching inductive devices such as magnetic solenoids or relay coils produces high-voltage flyback transients during OFF transitions. Technicians must install flyback diodes or RC suppression networks directly across inductive field loads to prevent degradation of internal sourcing transistors.\u003c\/p\u003e\n\u003cp\u003eQ: Are individual channels isolated from one another within the same wiring group?\u003c\/p\u003e\n\u003cp\u003eA: No point-to-point isolation exists between channels in the same 16-point group. All 16 points within a group share common DC power and reference ground connections, whereas galvanic isolation of 250 VAC continuous exists only between the two discrete channel groups and backplane logic circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module onto a compatible VersaMax carrier (IC200CHS series) fixed to a standard 35 mm DIN rail inside a protective industrial enclosure. Align the rear connector pins with the carrier backplane receptacle and press down firmly until the locking mechanism latches. Fasten field wiring to the carrier terminal block according to assigned channel numbers, ensuring dedicated DC supply connections for each 16-point group.\u003c\/p\u003e\n\u003cp\u003eSeparate DC output wiring runs from AC power lines, motor leads, and high-frequency inverter cabling within cabinet raceways. Maintain a minimum physical distance of 200 mm between low-voltage field output lines and heavy power conductors to reduce electromagnetic noise coupling. Before applying external 12\/24 VDC field power, clamp all field wiring shields to the cabinet ground bus and confirm proper termination of frame ground connections.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44536390484067,"sku":"IC200MDL750K","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/179.1_28753e91-4bd9-4b7d-acea-72b9a1f027ce.jpg?v=1788146907","url":"https:\/\/www.autocontrolglobal.com\/products\/ic200mdl750k-ge-versamax-32-point-24-vdc-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}