{"product_id":"ic200mdl930-ge-versamax-8-point-relay-output-module","title":"IC200MDL930 GE VersaMax 8-Point Relay Output Module","description":"\u003ch2\u003eGE IC200MDL930 VersaMax Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete load switching in VersaMax I\/O platforms, the \u003cstrong\u003eGE IC200MDL930\u003c\/strong\u003e (\u003cstrong\u003eIC200MDL930\u003c\/strong\u003e Relay Output Module) provides direct physical\/electrical execution. This high-density interface isolates control logic from harsh field transients while switching individual AC and DC actuator circuits. The module interfaces directly with the VersaMax backplane bus structure, providing reliable signal transitions across eight fully independent Form A contact channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE) \/ VersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 kg (0.69 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e27.8 cm x 21.2 cm x 2.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 30 deg C (without thermal derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e243 mA to 245 mA max backplane current (all outputs energized)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e8-Point Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003eNormally Open (Form A), silver alloy contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 125 VDC, 0 to 265 VAC (47 to 63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltages\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 24 VDC, 125 VDC, 120 VAC, 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating (Resistive)\u003c\/td\u003e\n\u003ctd\u003e2.0 A at 5 to 30 VDC; 0.2 A at 31 to 125 VDC; 2.0 A at 5 to 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Contact Load\u003c\/td\u003e\n\u003ctd\u003e10 mA resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous \/ 1500 VAC for 1 minute (optical and channel-to-channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum (On\/Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Frequency\u003c\/td\u003e\n\u003ctd\u003e20 cycles per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Standards\u003c\/td\u003e\n\u003ctd\u003eCE, cULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Velocity and I\/O Isolation Profiles\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL930 architecture integrates directly into the VersaMax backplane bus communication velocity framework, enabling high-speed deterministic parameter exchange between the CPU and field interface layers. Internal optocouplers deliver robust optical isolation from user input to logic and frame ground rated at 250 VAC continuous and 1500 VAC for up to one minute. Each individual output channel features complete channel-to-channel galvanic isolation, preventing severe electrical noise, voltage spikes, and ground loops on one field line from degrading adjacent circuits or corrupting backplane data integrity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the backplane current draw when all relay outputs are fully energized?\u003c\/p\u003e\n\u003cp\u003eA: The module draws up to 245 mA from the VersaMax backplane bus when all eight output points are simultaneously energized. System power budgets must account for this maximum current load to prevent backplane supply degradation.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module drive high-speed pulse-width modulation (PWM) or rapid switching applications?\u003c\/p\u003e\n\u003cp\u003eA: No. Due to mechanical armature dynamics, the maximum response time is 10 ms, and the switching frequency limit is capped at 20 cycles per minute for inductive loads. Solid-state output modules must be utilized for high-speed switching requirements.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IC200MDL930 contain internal fuses for overcurrent protection?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal relay contacts carry no integrated fusing or surge suppression components. External fuse blocks or inductive load suppression devices must be installed in series with each load circuit to prevent contact welding under short-circuit conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseboard Integration\u003c\/strong\u003e: Secure the module onto the VersaMax baseboard using the standard DIN-rail mounting slot or direct panel-mount tabs. Ensure the backplane connector pins align precisely prior to applying insertion force.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Isolation Separation\u003c\/strong\u003e: Route field-side AC and DC load wiring separately from sensitive low-voltage analog signal lines and communication cables to avoid inductive interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Fuse Protection\u003c\/strong\u003e: Install an appropriately rated external fast-acting fuse in series with each Form A contact point to safeguard silver alloy contacts against high-inrush currents or field wiring faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management\u003c\/strong\u003e: Operate the module strictly within 0 to 30 deg C ambient conditions when executing maximum simultaneous load switching. Maintain unblocked vertical airflow paths around the VersaMax rack assembly to ensure proper heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Standards\u003c\/strong\u003e: Connect the mounting rail and enclosure frame ground terminal directly to a single-point protective earth (PE) ground using a heavy-gauge copper conductor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44524086296675,"sku":"IC200MDL930","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/166._10546285-d844-4f7f-a611-76b8e3b5d632.jpg?v=1787883929","url":"https:\/\/www.autocontrolglobal.com\/products\/ic200mdl930-ge-versamax-8-point-relay-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}