{"product_id":"ic200udr001-ba-ge-fanuc-versamax-micro-programmable-logic-controller","title":"IC200UDR001-BA GE Fanuc VersaMax Micro Programmable Logic Controller","description":"\u003ch2\u003eGE Fanuc IC200UDR001-BA VersaMax Micro Controller\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete I\/O execution and local logic processing in standalone or networked automation systems, the \u003cstrong\u003eGE Fanuc IC200UDR001-BA\u003c\/strong\u003e (\u003cstrong\u003eIC200UDR001\u003c\/strong\u003e Micro Controller) provides direct physical\/electrical execution across industrial machinery platforms. The device executes high-speed logic sequencing via 8 DC input channels and 6 electromechanical relay output channels, interfacing directly with field switches, sensors, and actuators.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UDR001-BA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg (0.66 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e95 mm W x 76 mm D x 90 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e13 VA (120\/240 VAC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Range\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC (85-264 VAC line voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated I\/O Count\u003c\/td\u003e\n\u003ctd\u003e14 Points (8 DC Inputs, 6 Relay Outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e2.0 A per relay contact (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Memory\u003c\/td\u003e\n\u003ctd\u003e9K words logic memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegister Storage\u003c\/td\u003e\n\u003ctd\u003e256 words register memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Expansion I\/O\u003c\/td\u003e\n\u003ctd\u003e126 physical I\/O points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1x RJ-45 Port (RS-232, SNP \/ SNPX \/ Modbus RTU Slave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Scan Execution Rate\u003c\/td\u003e\n\u003ctd\u003e1.1 ms per 1K Boolean instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Trimmers\u003c\/td\u003e\n\u003ctd\u003e2 built-in potentiometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe unit features engineered backplane bus communication velocity drivers optimized for local expansion modules, enabling deterministic cycle times across connected expansion I\/O points up to the 126-point physical limit. Integrated serial hardware handles Modbus RTU Slave, SNP, and SNPX protocols over RS-232, maintaining deterministic firmware flash compatibility during online ladder logic updates via Proficy Machine Edition or VersaPro programming suites.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can expansion I\/O modules be hot-swapped during active CPU execution?\u003c\/p\u003e\n\u003cp\u003eA: No. The VersaMax Micro backplane bus does not support hot-swapping under live power. Removing or inserting expansion I\/O units while the controller operates can trigger memory corruption, system faults, or physical hardware damage. Power must be isolated prior to physical hardware reconfiguration.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum continuous current rating for the relay output channels, and is external suppression required?\u003c\/p\u003e\n\u003cp\u003eA: Relay outputs are rated for 2.0 A per channel continuous at 24 VDC \/ 240 VAC. Inductive loads such as solenoids or contactor coils require external RC snubbers or flyback diodes installed across the load to prevent contact erosion caused by voltage transients.\u003c\/p\u003e\n\u003cp\u003eQ: How are the integrated analog potentiometers mapped within the controller memory?\u003c\/p\u003e\n\u003cp\u003eA: The two built-in analog potentiometers scale internal register values directly without additional hardware programming, providing manual adjustment ranges mapped into system register memory for field tuning of timers and setpoints.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the unit on standard 35 mm DIN rails or directly onto a grounded steel backpanel using M4 hardware. Ensure a minimum clearance of 50 mm above and below the chassis for thermal convection airflow.\u003c\/li\u003e\n\u003cli\u003eConnect the main protective earth (PE) conductor directly to the dedicated earth terminal on the unit. Ensure a ground wire gauge of at least 2.0 mm sq (14 AWG) with low-impedance bonding.\u003c\/li\u003e\n\u003cli\u003eRoute low-voltage 24 VDC input wiring and serial communication cabling in cable ducts physically separated from high-voltage 120\/240 VAC power input and inductive relay output lines.\u003c\/li\u003e\n\u003cli\u003eGround all RS-232 communication cable shields at a single point at the host end only to avoid ground loops. Ensure all screw-clamp terminal connections are torqued to specified limits (0.5 to 0.6 Nm).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44453231853667,"sku":"IC200UDR001-BA","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/462._645e31a5-1394-4e61-92a9-6b4963a9d36a.jpg?v=1786082725","url":"https:\/\/www.autocontrolglobal.com\/products\/ic200udr001-ba-ge-fanuc-versamax-micro-programmable-logic-controller","provider":"AutoControl Global","version":"1.0","type":"link"}