GE Fanuc IC200UDR005 VersaMax Micro 28-Point PLC Unit
The GE Fanuc IC200UDR005-BB, also cataloged as the IC200UDR005 Micro 28 PLC Unit, operates as a dedicated hardware component for discrete/analog signal execution and sequential logic processing within VersaMax Micro control system platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IC200UDR005 |
| Brand | GE Fanuc / Emerson |
| Origin | Japan |
| Weight | 0.91 kg (2.00 lbs) |
| Dimensions | 150 x 76 x 90 mm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 26 VA |
| Input Voltage Rating | 120/240 VAC |
| Total Onboard I/O | 28 Points (16 Discrete Inputs, 12 Discrete Outputs) |
| Discrete Inputs | 16 points, 24 VDC |
| Discrete Outputs | 11 Relay outputs, 1 DC output (24 VDC) |
| Expansion Capacity | Up to 4 Discrete I/O units, up to 4 Analog I/O units (140 total physical I/O max) |
| User Program Memory | 9K Words (12 KB) logic memory |
| Register Memory | 2K Words (8 KB) data memory |
| Communication Ports | Port 1: RJ-45 RS-232; Port 2: DB-15 RS-485 |
| Serial Protocols | Port 1: SNP, SNP x; Port 2: SNP, SNP x, RTU Master/Slave, Serial Read/Write |
| Onboard Adjustments | 2 Analog potentiometers |
Backplane Expansion & Network Determinism
The unit integrates internal backplane bus communication velocity pathways to service onboard I/O execution while simultaneously driving external expansion headers. Through this local bus link, the controller coordinates real-time data frame transfers across up to 4 discrete expansion modules and 4 analog expansion modules without degrading central processing scan cycles.
Deterministic communications across physical layers are maintained via dual serial interfaces. Port 1 handles local programming and diagnostic throughput using RS-232 SNP/SNP x protocols, whereas Port 2 provides RS-485 multi-drop networking capability. The controller enforces predictable message response latencies over serial links when operating under Modbus RTU Master/Slave or SNP Master configurations, ensuring synchronized variable exchange between the main processing unit and downstream I/O nodes.
Frequently Asked Questions
Q: What programming software packages support logic execution development for the IC200UDR005?
A: Logic configuration requires VersaPro 1.1 or higher, or Proficy Machine Edition Logic Developer to compile and download ladder programs to memory.
Q: How many total physical I/O points can be managed by adding expansion modules?
A: The base unit supports up to 4 discrete and 4 analog expansion modules, allowing system scaling up to a maximum limit of 140 physical I/O points.
Q: What serial pinout interfaces are physically present on the micro controller chassis?
A: Channel communications utilize an RJ-45 connector for RS-232 signals on Port 1 and a DB-15 connector for RS-485 signals on Port 2.
Field Installation Guidelines
- Disconnect the main 120/240 VAC power source and verify the absence of line voltage before mounting the unit or terminating field wiring.
- Secure the PLC unit onto a standard 35 mm DIN rail or bolt the housing directly to the enclosure backpanel using the integrated mounting holes.
- Establish a low-impedance chassis ground connection from the grounding terminal directly to the enclosure ground bus bar.
- Route 24 VDC input lines and high-voltage AC relay output wires through separate wiring ducts to prevent inductive coupling noise.
- Terminate RS-232 or RS-485 communications cables using shielded twisted-pair conductors, grounding the cable shield at one end only.
- Apply AC operating power, verify that the unit power LED turns solid green, and initialize communication testing via Port 1.