{"product_id":"ic200uex011-b-ge-versamax-micro-expansion-module","title":"IC200UEX011-B GE VersaMax Micro Expansion Module","description":"\u003ch2\u003eGE IC200UEX011-B VersaMax Micro Expansion Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200UEX011-B\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200UEX011\u003c\/strong\u003e Micro Expansion Module, operates as a dedicated hardware component for extending discrete I\/O signal processing capacity within VersaMax Micro PLC systems. The expansion unit routes 8 discrete 24 VDC inputs and 6 relay outputs through direct bus attachment to a main VersaMax Micro controller base, operating on an integrated 100-240 VAC power supply.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UEX011-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.37 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.5 x 9.0 x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e13 VA typical input power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Input Power\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e8 points, 24 VDC nominal (Selectable positive\/negative logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e6 SPST Form A relay outputs (2 A per point, 5-30 VDC \/ 5-250 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Field Supply\u003c\/td\u003e\n\u003ctd\u003e+24 VDC isolated, 200 mA max output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e18 A at 120 VAC; 30 A at 200 VAC; 40 A at 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module executes local data exchanges via an expansion interconnect cable linked directly to the main Micro PLC backplane bus, transferring point states without decreasing backplane bus communication velocity across adjacent expansion bases. Internal hardware logic verifies controller firmware flash compatibility upon system startup, ensuring proper address allocation across up to 4 expansion units attached to a single host controller. Configurable input filter logic permits adjustment of signal response times between 0.5 ms and 20 ms to stabilize dirty sensor signals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power options exist for external field sensors attached to the input terminals?\u003c\/p\u003e\n\u003cp\u003eA: The expansion module features an onboard isolated auxiliary supply that provides +24 VDC at up to 200 mA to power dry contact switches and 2-wire field sensors directly without external power hardware.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module indicate output state transitions and operational faults?\u003c\/p\u003e\n\u003cp\u003eA: Individual green LEDs on the front panel display active states for all 8 inputs and 6 relay outputs. System status is monitored via the OK LED for backplane health and the FLD PWR LED for field power presence.\u003c\/p\u003e\n\u003cp\u003eQ: What are the electrical isolation thresholds for field-to-logic wiring on this module?\u003c\/p\u003e\n\u003cp\u003eA: Internal optocouplers and isolation barriers provide 1500 V RMS galvanic isolation between field terminal points and logic circuits, along with 500 V RMS isolation between channel groups.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the expansion module adjacent to the primary VersaMax Micro PLC on a grounded 35 mm DIN rail or attach it directly to a panel surface using mounting screws. Connect the ribbon cable between the side expansion port of the main unit and the input port of the expansion module to maintain serial bus connectivity.\u003c\/p\u003e\n\u003cp\u003eConnect 100-240 VAC primary utility power to the designated supply terminals using minimum 18 AWG copper conductors. Separate AC output load wiring from DC signal conductors by at least 200 mm to reduce inductive coupling. De-energize all AC line power and field supplies before connecting conductors or replacing units in Class I, Div 2 hazardous locations.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44536608587875,"sku":"IC200UEX011-B","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/208._e94d052f-fc21-4462-8d3f-a2530a7bed45.jpg?v=1788155212","url":"https:\/\/www.autocontrolglobal.com\/products\/ic200uex011-b-ge-versamax-micro-expansion-module","provider":"AutoControl Global","version":"1.0","type":"link"}