IC660BBA104 GE Fanuc Genius I/O Analog Input Output Block
IC660BBA104 GE Fanuc Genius I/O Analog Input Output Block
IC660BBA104 GE Fanuc Genius I/O Analog Input Output Block
/ 3

IC660BBA104 GE Fanuc Genius I/O Analog Input Output Block

  • Manufacturer: GE Fanuc

  • Part Number: IC660BBA104

  • Condition:New with Original Package

  • Product Type: Analog Input Output Blocks

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE IC660BBA104 Genius I/O Analog Block

The GE IC660BBA104, also cataloged as the IC660BBA104 Analog Input/Output Block, operates as a dedicated hardware component for direct sensor signal digitization and execution within Genius I/O network architectures.

Hardware Specifications

Parameter Specification
Model IC660BBA104
Brand GE Fanuc
Origin USA
Weight 3.88 lbs (1.76 kg)
Dimensions 8.83 x 3.56 x 4.42 inches
Operating Temp 0 to 60 deg C
Power Consumption 12 Watts
Block Power (Nominal) 115 VAC / 125 VDC
Block Power (Input Range) 93-132 VAC / 105-145 VDC
Input Channels 6 current source inputs
Output Channels 2 outputs
Input Signal Range 4-20 mA
Input Signal Resolution 1 uA
Output Signal Resolution 6 uA
Input Accuracy 0.1% of full-scale reading
Output Accuracy 0.15% of full-scale reading
Input Conversion Time 16.6 ms to 400 ms (selectable)
Block-to-Block Isolation 1500 V RMS
Bus Interface Genius RS-485 serial bus
Status Indicators Unit OK, I/O Enabled LEDs

Backplane Bus & Network Determinism

The IC660BBA104 relies on the proprietary Genius RS-485 serial bus protocol to establish deterministic token-passing communication across industrial control networks. High-density I/O integration requires strict packet timing execution, allowing field measurements to transmit to host PLCs like the Series 90-30 or 90-70 without backplane latency degradation. Internal firmware flash compatibility ensures that configurable parameters—such as the input conversion filter times spanning 16.6 ms to 400 ms—synchronize directly with block diagnostic logic while maintaining galvanically isolated channel states against network ground loops.

Frequently Asked Questions

Q: How does block-to-block isolation impact ground fault conditions?

A: The 1500 V block-to-block isolation breaks electrical continuous paths between field sensor loops and the Genius RS-485 bus network. This prevents transient high-voltage surges or common-mode ground noise from propagating back to the central controller.

Q: What happens to output states during a serial bus communication interruption?

A: When serial transmission drops, the onboard microprocessor detects a bus timeout and forces the outputs into a pre-configured fail-safe state or holds the last valid value based on software configuration, preventing uncommanded actuator movement.

Field Installation Guidelines

Mount the IC660BBA104 vertically on a grounded metal sub-panel to maximize natural convection cooling across the housing heat sink structure. Ensure all Genius RS-485 network cabling utilizes shielded twisted-pair wire, terminating the shield drain wire at the designated bus block ground terminal only to prevent circulating ground currents. Strip input wires to specification and torque field terminals securely to ensure low-resistance contact for 4-20 mA loop connections. Maintain a minimum clearance of 2 inches on all sides for passive thermal dissipation and routing of field wiring harnesses.

You may also like