{"product_id":"ic670mdl241-ge-fanuc-field-control-input-module","title":"IC670MDL241 GE Fanuc Field Control Input Module","description":"\u003ch2\u003eGE Fanuc IC670MDL241 Field Control Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for converting high-voltage field signals into logic states in Field Control automation systems, the \u003cstrong\u003eGE Fanuc IC670MDL241\u003c\/strong\u003e (\u003cstrong\u003eIC670MDL241J\u003c\/strong\u003e Input Module) provides direct physical signal processing across 16 discrete channels. It converts 240 VAC inputs into logic-level data for transmission across the Bus Interface Unit backplane.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number \/ Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eHardware Revision \u0026amp; Status Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC670MDL241\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Field Control 240 VAC 16-Point Discrete Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC670MDL241J\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecific Field Control Revision Variant Identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL241 (Revision Variant: IC670MDL241J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg (0.60 lbs - 0.63 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e54 mm x 85 mm x 80 mm (5.4 cm x 8.5 cm x 8.0 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e77 mA maximum draw from Bus Interface Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e240 VAC (Operating range: 0-265 VAC, 47-63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16 discrete channels (Organized in 2 isolated groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Input Current\u003c\/td\u003e\n\u003ctd\u003e8.2 mA per point at 240 VAC (On-state: 4.0-10 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e155 VAC to 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 VAC to 40 VAC (Off-state current: 0-1.5 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e20 ms maximum (On-to-Off and Off-to-On)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous (1500 VAC for 1 minute test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Terminals\u003c\/td\u003e\n\u003ctd\u003eScrew-type terminal block accepting 14 to 22 AWG wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC670MDL241 executes deterministic signal processing across high-density I\/O arrays while maintaining firmware flash compatibility with standard Field Control Bus Interface Units. Local optical isolation barriers and RC filtering networks condition high-voltage AC inputs to preserve backplane bus communication velocity and prevent electrical noise propagation into the central logic processor.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC670MDL241 draw its operational field power directly from the backplane bus?\u003c\/p\u003e\n\u003cp\u003eA: No. The backplane Bus Interface Unit supplies up to 77 mA for internal logic processing, but external 240 VAC field power must be supplied directly to each isolated input group.\u003c\/p\u003e\n\u003cp\u003eQ: How are the 16 discrete input channels isolated from each other?\u003c\/p\u003e\n\u003cp\u003eA: The channels are divided into two independent groups of eight points (1-8 and 9-16), providing galvanic isolation up to 250 VAC continuous between groups, to logic ground, and to frame ground.\u003c\/p\u003e\n\u003cp\u003eQ: What wire gauge range does the field wiring connector accommodate?\u003c\/p\u003e\n\u003cp\u003eA: The removable screw terminal block accepts field wiring sizes ranging from 14 AWG to 22 AWG.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all primary rack power and field-side 240 VAC voltage sources prior to installing or servicing the input module.\u003c\/li\u003e\n\u003cli\u003eVerify that the terminal block wiring maintains strict isolation between 240 VAC high-voltage AC field lines and low-voltage logic control wiring.\u003c\/li\u003e\n\u003cli\u003eConnect field conductors within the specified 14 to 22 AWG wire gauge range and torque screw terminals properly to prevent loose high-voltage connections.\u003c\/li\u003e\n\u003cli\u003eEnsure each group of eight inputs receives proper phase line and neutral terminations according to system schematics.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate vertical ventilation spacing around the subrack enclosure to operate within the 0 deg C to +60 deg C temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44510797463651,"sku":"IC670MDL241","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/142._37ca75e7-d151-4e8e-95c3-32e6e76ff2f7.jpg?v=1787639431","url":"https:\/\/www.autocontrolglobal.com\/products\/ic670mdl241-ge-fanuc-field-control-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}