{"product_id":"ic693bem340-ef-ge-series-90-30-fip-communication-module","title":"IC693BEM340-EF GE Series 90-30 FIP Communication Module","description":"\u003ch2\u003eGE Fanuc IC693BEM340-EF Series 90-30 FIP Bus Controller Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693BEM340-EF\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693BEM340\u003c\/strong\u003e FIP Bus Controller Module, operates as a dedicated hardware component for deterministic remote I\/O data processing and serial communication within Series 90-30 PLC backplanes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693BEM340-EF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg (500 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e132 x 36 x 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.4 A at +5 VDC (2 W, backplane supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eFIP bus protocol (cyclic, deterministic execution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interfaces\u003c\/td\u003e\n\u003ctd\u003eDual 9-pin D-sub connectors, single RS-485 serial service port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Series 90-30, Series 90-70 PLCs, Field Control Stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Redundant Network Execution\u003c\/h3\u003e\n\u003cp\u003eThe module manages remote node data exchange by interfacing directly across the Series 90-30 backplane bus, offloading cyclical I\/O polling, configuration storage, and fault reporting from the main system CPU. Dual 9-pin front connectors support primary and secondary physical bus channels, allowing automatic media failover across redundant network paths. Firmware flash compatibility via the front-panel RS-485 service port enables direct maintenance updates without requiring physical module removal. Furthermore, the controller scales I\/O density by coordinating data flow between baseplate racks, remote drops, and Series 90-70 hosts through Bus Interface Units (BIUs) or Remote I\/O Scanners. Front-panel status LEDs display real-time bus traffic, hardware readiness, and communication activity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the IC693BEM340-EF handle physical communication path redundancy on the FIP network?\u003c\/p\u003e\n\u003cp\u003eA: The controller features dual 9-pin D-sub interfaces on the front panel, allowing simultaneous connection to primary and backup FIP serial cable runs without auxiliary hardware.\u003c\/p\u003e\n\u003cp\u003eQ: What function does the front-panel RS-485 serial service port perform?\u003c\/p\u003e\n\u003cp\u003eA: Technicians utilize the RS-485 port for direct parameter configuration and executing firmware flash updates using standard software tools.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IC693BEM340-EF allowed to be installed or removed under backplane power?\u003c\/p\u003e\n\u003cp\u003eA: No. System power to the Series 90-30 baseplate rack must be disconnected prior to inserting or removing the module to prevent electrical damage to backplane connector pins.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003ePower down the Series 90-30 baseplate before installing the module into its target rack slot. Slide the module board along the card guides until the backplane edge connector seats fully into the baseplate receptacle, then lock the upper and lower housing latches.\u003c\/p\u003e\n\u003cp\u003eConnect primary and redundant FIP network cables to the dual 9-pin D-sub ports on the front face. Route all signal and serial service cabling through dedicated, grounded wire channels, keeping a minimum distance of 200 mm from high-voltage AC conductors and drive units. Ground all cable shield drains to a single low-impedance earth point near the rack chassis to prevent ground loops. Ensure unobstructed vertical airflow through the enclosure to maintain internal ambient temperatures between 0 deg C and +60 deg C.\u003c\/p\u003e\n\u003ch3\u003eSEO Suite\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSEO Title Option 1:\u003c\/strong\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43876925767779,"sku":"IC693BEM340-EF","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/124_87fd119b-4ded-4967-8f11-a8cbf7c5a6db.jpg?v=1765181841","url":"https:\/\/www.autocontrolglobal.com\/products\/ic693bem340-ef-ge-series-90-30-fip-communication-module","provider":"AutoControl Global","version":"1.0","type":"link"}