{"product_id":"ic693chs397l-ge-fanuc-9-slot-baseplate-new-original-stock","title":"IC693CHS397L GE Fanuc 9-Slot Baseplate | New \u0026 Original Stock","description":"\u003ch2\u003eGE Fanuc IC693CHS397L Series 90-30 PLC\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CHS397L\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693CHS397\u003c\/strong\u003e 9-Slot Baseplate, operates as a dedicated hardware component for module housing and backplane communication execution within Series 90-30 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CHS397L (Base Model: IC693CHS397)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg (2.5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e445 mm x 140 mm x 20 mm (17.5 in x 5.5 in x 0.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDerived from the installed Series 90-30 power supply module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Type\u003c\/td\u003e\n\u003ctd\u003e9-slot baseplate (1 dedicated power supply slot, 1 dedicated CPU slot, 7 I\/O and option slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eHorizontal panel mounting only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537109070\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and System Constraints\u003c\/h3\u003e\n\u003cp\u003eThe IC693CHS397L utilizes an integrated high-speed parallel backplane bus to execute deterministic data transfer across the physical I\/O infrastructure. Firmware flash compatibility across connected modules depends entirely on the processing metrics of the CPU inserted into slot 1. The electrical bus lines handle high I\/O density scaling up to 7 distinct option modules, preventing impedance mismatches through structured track termination within the chassis. Power routing is localized, establishing solid bus communication velocity without external bridging cables inside a single rack footprint.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC693CHS397L baseplate be mounted vertically in high-density enclosures?\u003c\/p\u003e\n\u003cp\u003eA: No. The chassis architecture relies on natural convection cooling and must be mounted horizontally. Vertical mounting alters the thermal dissipation profile, creating heat stagnation points that invalidate the 0 to 60 deg C operating specifications.\u003c\/p\u003e\n\u003cp\u003eQ: Does this chassis support hot-swapping of I\/O or CPU modules during active backplane operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The Series 90-30 backplane architecture does not feature live electronic insertion or removal capabilities. The system power supply must be completely de-energized before inserting or removing any module to prevent backplane bus damage or data corruption.\u003c\/p\u003e\n\u003cp\u003eQ: How is the current load distributed across the backplane slots?\u003c\/p\u003e\n\u003cp\u003eA: The physical backplane distributes voltage rails directly from the power supply module located in the leftmost slot. The combined current draw of the CPU and all 7 option modules must not exceed the maximum current output ratings specified for the installed power supply module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding:\u003c\/strong\u003e Secure the baseplate to a grounded metallic subpanel using internal star washers on the mounting screws to ensure low-impedance electrical contact. A dedicated copper grounding strap must run from the chassis ground terminal to the main enclosure earth ground bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpacing Requirements:\u003c\/strong\u003e Maintain a minimum clearance of 50 mm (2 inches) on all sides of the baseplate chassis to ensure unhindered natural convection airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the printed circuit board edge connectors with the plastic chassis guides before applying structural pressure. Ensure the module locking mechanisms are fully engaged with the baseplate frame to prevent intermittent bus connection failures under high-vibration conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Segregation:\u003c\/strong\u003e Route all high-voltage AC and high-current DC field wiring through wire ducts separated from the low-voltage parallel backplane lines and adjacent communication cables to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44242431344739,"sku":"IC693CHS397L","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/44._433f3865-ce2a-4bb4-96da-9f4c39cdb739.jpg?v=1780988585","url":"https:\/\/www.autocontrolglobal.com\/products\/ic693chs397l-ge-fanuc-9-slot-baseplate-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}