{"product_id":"ic693cmm302p-ge-series-90-30-communication-modules","title":"IC693CMM302P GE Series 90-30 Communication Modules","description":"\u003ch2\u003eGE Fanuc IC693CMM302P Series 90-30 Enhanced Genius Communications Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CMM302P\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693CMM302\u003c\/strong\u003e Enhanced Genius Communications Module, operates as a dedicated hardware component for peer-to-peer global data transfer within Series 90-30 PLC platforms. Installed in a standard option slot on a CPU, expansion, or remote baseplate, the module transfers up to 128 bytes of transmit and 128 bytes of receive data across token-passing Genius bus networks without burdening the primary CPU sweep cycle.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CMM302P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Production\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 33 x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;300 mA @ 5 VDC backplane draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eIC693CMM302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Data Capacity\u003c\/td\u003e\n\u003ctd\u003e128 bytes transmit, 128 bytes receive per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eGenius bus token-passing peer-to-peer \/ Ethernet interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Network Nodes\u003c\/td\u003e\n\u003ctd\u003e31 devices per Genius bus (up to 62 devices per PLC with dual modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 VDC isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Memory Types\u003c\/td\u003e\n\u003ctd\u003e%G, %I, %Q, %AI, %AQ, %R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eStatus LEDs (OK, COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC693CMM302P exchanges global data packets directly over the backplane bus, preserving backplane bus communication velocity while maintaining deterministic real-time data sync across distributed racks. Dedicated onboard processing offloads network protocol execution from the host processor, while firmware flash compatibility ensures seamless instruction alignment with Series 90-30, Series 90-70, and Series Six PLC controllers across system revisions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the IC693CMM302P module handle hot-swapping or baseplate slot restrictions during maintenance?\u003c\/p\u003e\n\u003cp\u003eA: The IC693CMM302P must be installed or removed only when baseplate power is completely switched off. It occupies a single I\/O slot and functions in any slot except the dedicated CPU slot on slot-based baseplates.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum node capacity supported when deploying the IC693CMM302P in a Series 90-30 system?\u003c\/p\u003e\n\u003cp\u003eA: A single IC693CMM302P module connects up to 31 Genius bus devices. By installing two modules in a single PLC rack, the total supported node capacity scales up to 62 devices.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure system backplane power is entirely disconnected prior to inserting or seating the communication module into the selected rack slot.\u003c\/li\u003e\n\u003cli\u003eRoute Genius bus shielded twisted-pair cabling away from high-voltage AC power lines and variable frequency drive output conduits to minimize noise interference.\u003c\/li\u003e\n\u003cli\u003eTerminate both physical ends of the Genius bus network using 75 Ohm or 100 Ohm terminating resistors matched to cable impedance.\u003c\/li\u003e\n\u003cli\u003eAttach the cable shield drain wire directly to a clean panel protective earth ground point to maintain 1500 VDC galvanic isolation performance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44563557515363,"sku":"IC693CMM302P","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/67._f04033cf-9016-447f-af88-2880a22350d6.jpg?v=1788742947","url":"https:\/\/www.autocontrolglobal.com\/products\/ic693cmm302p-ge-series-90-30-communication-modules","provider":"AutoControl Global","version":"1.0","type":"link"}