{"product_id":"ic693cpu364-cf-ge-fanuc-series-90-30-cpu-processor-module","title":"IC693CPU364-CF GE Fanuc Series 90-30 CPU Processor Module","description":"\u003ch2\u003eGE Fanuc IC693CPU364-CF Series 90-30 CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CPU364-CF\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIC693CPU364\u003c\/strong\u003e CPU Module utilized to execute central control logic processing and Ethernet network integration across Series 90-30 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CPU364-CF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg (0.66 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e135 mm x 127 mm x 33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane 5 VDC bus load from main rack supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicroprocessor\u003c\/td\u003e\n\u003ctd\u003eIntel 80386EX operating at 25 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Scan Rate\u003c\/td\u003e\n\u003ctd\u003e0.22 ms per 1K Boolean logic instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Program Memory\u003c\/td\u003e\n\u003ctd\u003e240 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData \/ Register Memory\u003c\/td\u003e\n\u003ctd\u003e10K words data, 128 to 32,640 words register memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e10Base-T (via AAUI interface), TCP\/IP protocol support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003eRS-232 and RS-485 via power supply connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe central processing module coordinates process control tasks by routing input and output data tables directly through the backplane bus communication velocity architecture. Operating with a typical scan rate of 0.22 milliseconds per 1K Boolean instructions, the module minimizes processing overhead while executing complex control loops. Onboard flash memory maintains strict firmware flash compatibility across attached expansion racks, allowing synchronized data transfers over the AAUI Ethernet port to external SCADA networks without interrupting real-time logic execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What transceiver interface does the IC693CPU364-CF require for standard RJ-45 Ethernet connection?\u003c\/p\u003e\n\u003cp\u003eA: The onboard Ethernet port utilizes an AAUI (Apple Attachment Unit Interface) connector, requiring an external AAUI-to-10Base-T transceiver to connect to standard RJ-45 twisted-pair network cables.\u003c\/p\u003e\n\u003cp\u003eQ: How does the CPU handle user memory preservation during system power shutdowns?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on a lithium battery backup circuit located in the rack power supply module to maintain user program memory, register tables, and real-time clock values when primary line power is removed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the single-slot CPU module into slot 1 of a standard Series 90-30 baseplate rack, ensuring the rear backplane pin header engages fully before locking the module retaining clips. Connect the AAUI Ethernet transceiver and route network cabling through dedicated wire ducts, maintaining physical separation from high-voltage AC lines and motor drive wiring to minimize electromagnetic interference. Field technicians must connect the rack grounding terminal to the panel earthing busbar using a low-impedance copper conductor and verify that ambient enclosure temperatures remain within 0 deg C to +60 deg C prior to energizing the backplane.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43876823957603,"sku":"IC693CPU364-CF","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/45_d660ffe6-d804-4673-9483-18ce700ed439.jpg?v=1765173350","url":"https:\/\/www.autocontrolglobal.com\/products\/ic693cpu364-cf-ge-fanuc-series-90-30-cpu-processor-module","provider":"AutoControl Global","version":"1.0","type":"link"}