{"product_id":"ic693mdl752d-ge-series-90-30-32-point-relay-output-module","title":"IC693MDL752D GE Series 90-30 32-Point Relay Output Module","description":"\u003ch2\u003eGE Fanuc IC693MDL752D Series 90-30 Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal switching in Series 90-30 PLC platforms, the \u003cstrong\u003eGE Fanuc IC693MDL752D\u003c\/strong\u003e (\u003cstrong\u003eIC693MDL752\u003c\/strong\u003e Relay Output Module) provides direct physical\/electrical execution. This single-slot module delivers 32 Form A (SPST-NO) relay output channels, interfacing field devices such as solenoids, contactors, and indicators to the central processing unit over the backplane. Operating across voltage ranges of 120\/240 V AC or 24 V DC, it supports switching loads up to 2 A per point with 1500 V AC galvanic isolation between output circuits and internal PLC logic.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL752D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (0.63 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.1 cm x 14.0 cm x 12.7 cm (1.6 in x 5.5 in x 5.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA at 5 VDC (from backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Count\u003c\/td\u003e\n\u003ctd\u003e32 Form A (SPST-NO) relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 V AC or 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e2 A per point max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V AC output-to-logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e10 ms max (operate\/release)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe IC693MDL752D output module utilizes a high-density channel layout to maximize backplane bus communication efficiency within standard Series 90-30 rack assemblies. Deterministic backplane logic execution ensures rapid update cycles, sending output status commands to the field contacts with maximum operate\/release latencies of 10 ms. The architecture optimizes I\/O density scaling while maintaining rigorous isolation standards to protect internal processor buses from field noise, voltage surges, and back-EMF spikes generated by inductive loads.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum current rating supported per channel on the IC693MDL752D?\u003c\/p\u003e\n\u003cp\u003eA: Each individual relay output channel supports a maximum current load of 2 A per point across either 120\/240 V AC or 24 V DC operating conditions.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC693MDL752D module be inserted or removed while the PLC backplane is powered?\u003c\/p\u003e\n\u003cp\u003eA: No, the Series 90-30 architecture requires removing power from the baseplate before installing or extracting the module to avoid backplane bus communication errors or damage to electrical contacts.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module maintain logic safety against field-side electrical noise?\u003c\/p\u003e\n\u003cp\u003eA: The board incorporates 1500 V AC isolation between field output wiring and the internal PLC backplane logic circuitry to suppress common-mode electrical transients.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Supplies\u003c\/strong\u003e: Verify that main rack power and field supply voltages are de-energized prior to seating or unseating the module in the baseplate slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eObserve Inductive Load Protection\u003c\/strong\u003e: Install external suppression circuits, such as RC networks for AC switching or freewheeling diodes for DC switching, directly across inductive field loads to prevent contact pitting and mechanical relay fatigue.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Conduit Separation\u003c\/strong\u003e: Route high-voltage output field wiring in separate conduits or wireways from low-level analog or communication cables to avoid inductive cross-talk and noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44567069425763,"sku":"IC693MDL752D","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/251._7cf0e24a-d307-4093-8226-9d4a4bf26089.jpg?v=1788851391","url":"https:\/\/www.autocontrolglobal.com\/products\/ic693mdl752d-ge-series-90-30-32-point-relay-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}