IC693MDL930F GE Fanuc Series 90-30 Isolated Relay Output Module
Manufacturer: GE Fanuc
-
Part Number: IC693MDL930F
Condition:New with Original Package
Product Type: Digital Output Modules
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
GE Fanuc IC693MDL930F Series 90-30 Isolated Relay Output Module
Configured for discrete control execution in GE Fanuc Series 90-30 PLC platforms, the GE Fanuc IC693MDL930F (IC693MDL930 Isolated Relay Output Module) provides direct physical/electrical execution. The hardware operates eight independent, normally-open relay circuits that drive AC and DC field devices such as motor starters, solenoids, and indicator lamps. Individual green light-emitting diodes display real-time logic-side contact activation. A red color-coded faceplate insert signifies high-voltage field potential to prevent physical mis-wiring during module maintenance.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IC693MDL930F |
| Brand | GE Fanuc |
| Origin | United States |
| Weight | 0 lbs 8.0 oz (0.2 kg) |
| Dimensions | 2.0 in x 5.0 in x 5.0 in (5.1 cm x 12.7 cm x 12.7 cm) |
| Operating Temp | 0 deg C to 60 deg C |
| Power Consumption | 6 mA (5 VDC logic bus), 70 mA (24 VDC relay bus) |
| Output Points | 8 normally-open isolated circuits |
| Rated Voltage | 24 VDC, 120/240 VAC nominal |
| Operating Voltage Range | 5-30 VDC, 5-250 VAC (50/60 Hz) |
| Max Load per Output | 4 A resistive, 2 A pilot duty |
| Max Load per Module | 20 A total |
| Min Load | 10 mA |
| Max Inrush Current | 5 A |
| Isolation | 1500 V field to logic side, 500 V channel-to-channel |
| Turn-On / Turn-Off Time | 15 ms max |
Industrial PLC Control & Module Diagnostics
The module integrates directly into the GE Series 90-30 backplane bus to ensure rapid firmware flash compatibility and deterministic signal transfer to the central processing unit. Signal routing features channel-to-channel isolation that prevents ground loops and electrical interference from migrating across field circuits. Power from the internal backplane bus provides logic control, while field devices draw operating power through independent user-supplied supplies. High I/O density scaling allows installation across any standard I/O slot in 5-slot or 10-slot Series 90-30 baseplates without requiring external bus expansion hardware.
Frequently Asked Questions
Q: Can engineers replace the IC693MDL930F module while the Series 90-30 baseplate remains energized?
A: No, this module is not hot-swappable. Technicians must completely remove power from both the PLC backplane and the field-side relay circuits before inserting or removing the hardware to prevent backplane bus damage or arc flash risks.
Q: Does the IC693MDL930F include internal current-limiting fuses for output point protection?
A: No, the module does not contain internal fuse protection on the relay contact points. Installing external inline fast-acting fuses rated for specific load profiles is necessary to safeguard the relay contacts against overcurrent and short-circuit faults.
Field Installation Guidelines
Mounting the IC693MDL930F requires aligning the module terminal block with the baseplate backplane connector, sliding the module backward until the top and bottom holding clips snap securely into the rack slot. Maintain strict separation between high-voltage field wiring and low-voltage signal lines within the wiring duct to eliminate inductive coupling. Connect dedicated, individual common lines for each output point when switching isolated voltage sources. Verify that all field ground cables follow single-point grounding rules to prevent ground loop potential across channels. Ensure ambient enclosure airflow maintains operating temperatures below 60 deg C, and apply load derating principles when running high current loads concurrently in elevated temperature conditions.