{"product_id":"ic693mdl930f-ge-fanuc-series-90-30-isolated-relay-output-module","title":"IC693MDL930F GE Fanuc Series 90-30 Isolated Relay Output Module","description":"\u003ch2\u003eGE Fanuc IC693MDL930F Series 90-30 Isolated Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete control execution in GE Fanuc Series 90-30 PLC platforms, the \u003cstrong\u003eGE Fanuc IC693MDL930F\u003c\/strong\u003e (\u003cstrong\u003eIC693MDL930\u003c\/strong\u003e Isolated Relay Output Module) provides direct physical\/electrical execution. The hardware operates eight independent, normally-open relay circuits that drive AC and DC field devices such as motor starters, solenoids, and indicator lamps. Individual green light-emitting diodes display real-time logic-side contact activation. A red color-coded faceplate insert signifies high-voltage field potential to prevent physical mis-wiring during module maintenance.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL930F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0 lbs 8.0 oz (0.2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.0 in x 5.0 in x 5.0 in (5.1 cm x 12.7 cm x 12.7 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 mA (5 VDC logic bus), 70 mA (24 VDC relay bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e8 normally-open isolated circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 120\/240 VAC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5-30 VDC, 5-250 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load per Output\u003c\/td\u003e\n\u003ctd\u003e4 A resistive, 2 A pilot duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load per Module\u003c\/td\u003e\n\u003ctd\u003e20 A total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Load\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inrush Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V field to logic side, 500 V channel-to-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-On \/ Turn-Off Time\u003c\/td\u003e\n\u003ctd\u003e15 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial PLC Control \u0026amp; Module Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe module integrates directly into the GE Series 90-30 backplane bus to ensure rapid firmware flash compatibility and deterministic signal transfer to the central processing unit. Signal routing features channel-to-channel isolation that prevents ground loops and electrical interference from migrating across field circuits. Power from the internal backplane bus provides logic control, while field devices draw operating power through independent user-supplied supplies. High I\/O density scaling allows installation across any standard I\/O slot in 5-slot or 10-slot Series 90-30 baseplates without requiring external bus expansion hardware.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can engineers replace the IC693MDL930F module while the Series 90-30 baseplate remains energized?\u003c\/p\u003e\n\u003cp\u003eA: No, this module is not hot-swappable. Technicians must completely remove power from both the PLC backplane and the field-side relay circuits before inserting or removing the hardware to prevent backplane bus damage or arc flash risks.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IC693MDL930F include internal current-limiting fuses for output point protection?\u003c\/p\u003e\n\u003cp\u003eA: No, the module does not contain internal fuse protection on the relay contact points. Installing external inline fast-acting fuses rated for specific load profiles is necessary to safeguard the relay contacts against overcurrent and short-circuit faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMounting the IC693MDL930F requires aligning the module terminal block with the baseplate backplane connector, sliding the module backward until the top and bottom holding clips snap securely into the rack slot. Maintain strict separation between high-voltage field wiring and low-voltage signal lines within the wiring duct to eliminate inductive coupling. Connect dedicated, individual common lines for each output point when switching isolated voltage sources. Verify that all field ground cables follow single-point grounding rules to prevent ground loop potential across channels. Ensure ambient enclosure airflow maintains operating temperatures below 60 deg C, and apply load derating principles when running high current loads concurrently in elevated temperature conditions.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44478692130915,"sku":"IC693MDL930F","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/41._5232c41a-abea-464d-ab96-59ac416fabf3.jpg?v=1786606070","url":"https:\/\/www.autocontrolglobal.com\/products\/ic693mdl930f-ge-fanuc-series-90-30-isolated-relay-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}