{"product_id":"ic693pbm200-emerson-90-30-plc-profibus-interface-card","title":"IC693PBM200 Emerson 90-30 PLC PROFIBUS Interface Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC693PBM200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the high-speed communication gateway for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSeries 90-30 PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems, enabling seamless integration with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS-DP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enetworks. This module functions as a Class 1 Master, allowing the PLC to orchestrate distributed I\/O, motor starters, and intelligent field devices. By offloading complex network management from the CPU, the IC693PBM200 maintains high system throughput even when managing up to 125 slave devices. It provides the essential link for modernizing legacy 90-30 architectures within multi-vendor automation environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC693PBM200 facilitates high-bandwidth data exchange across the industrial plant floor:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC693PBM200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries 90-30 PLC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS-DP (Master)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rates\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.6 Kbps to 12 Mbps (Auto-sensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Data Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e244 Bytes per Slave\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Data Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e244 Bytes per Slave\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Slave Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 DP Slaves\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9-pin Sub-D Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e450 mA @ 5V DC (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eService Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne (1) RS-232 Port for local diagnostics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Determinism:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports the maximum PROFIBUS specification of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12 Mbps\u003c\/strong\u003e. This ensures low-latency synchronization between the central 90-30 PLC and remote I\/O drops, which is vital for high-speed packaging and motion-sensitive applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMassive Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy supporting up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e125 DP slaves\u003c\/strong\u003e, a single IC693PBM200 eliminates the need for multiple communication cards. Engineers can expand the network using standard repeaters to cover vast distances across utilities or manufacturing plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Network Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module maintains a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSlave Status Bit Array table\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand internal diagnostic counters. These tools allow operators to identify specific network failures or faulty slave nodes directly from the PLC registers, drastically reducing troubleshooting time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Hardware Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC693PBM200 fits into any standard Series 90-30 baseplate slot. It utilizes the standard GE Fanuc programming environment for configuration, ensuring that existing logic and hardware remain compatible during network expansions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does the IC693PBM200 support PROFIBUS-PA devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC693PBM200 communicates natively via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS-DP\u003c\/strong\u003e. To connect PROFIBUS-PA field instruments (commonly used in hazardous areas), you must use a DP\/PA segment coupler. The Master module will then recognize the PA devices as standard DP nodes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is special software required to configure the PROFIBUS network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. You require a GSD (General Station Description) file for every slave device on the network. You import these into the GE Fanuc configuration tool (such as Proficy Machine Edition) to define the I\/O mapping and baud rates for the IC693PBM200.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do I handle the termination of the PROFIBUS line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe PROFIBUS standard requires active termination at both physical ends of the cable run. Ensure the 9-pin Sub-D connector attached to the IC693PBM200 has the termination switch set to \"ON\" if the module sits at the end of the segment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can this module function as a PROFIBUS Slave?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The IC693PBM200 is a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMaster Module\u003c\/strong\u003e. If you need to connect a Series 90-30 PLC as a slave to another master (such as a Siemens S7 or an RX3i), you must use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693PBS201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSlave Module instead.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44149326872675,"sku":"IC693PBM200","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/536_8adeda33-c2c0-4993-9cdc-fe3fa22b3af8.jpg?v=1777518094","url":"https:\/\/www.autocontrolglobal.com\/products\/ic693pbm200-emerson-90-30-plc-profibus-interface-card","provider":"AutoControl Global","version":"1.0","type":"link"}