{"product_id":"ic693pwr321t-ge-fanuc-series-90-30-datasheet-technical-manual","title":"IC693PWR321T GE Fanuc Series 90-30 Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eGE Fanuc IC693PWR321T Series 90-30 PLC Power Supply\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693PWR321T\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693PWR321\u003c\/strong\u003e Standard Power Supply, operates as a dedicated hardware component for voltage regulation and electrical distribution within Series 90-30 PLC baseplates.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693PWR321T \/ IC693PWR321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (Emerson Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.51 kg (1.13 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130.0 mm x 152.0 mm x 140.0 mm (5.12 in x 6.0 in x 5.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput: 90 VA (AC) \/ 50 W (DC); Total Load Capacity: 30 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC or 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range, AC\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range, DC\u003c\/td\u003e\n\u003ctd\u003e100 to 300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4 A peak, 250 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs Provided\u003c\/td\u003e\n\u003ctd\u003e3 outputs (5 VDC, 24 VDC Relay, 24 VDC Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 VDC Output Capacity\u003c\/td\u003e\n\u003ctd\u003e15 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC Relay Output\u003c\/td\u003e\n\u003ctd\u003e15 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC Isolated Output\u003c\/td\u003e\n\u003ctd\u003e20 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup Time\u003c\/td\u003e\n\u003ctd\u003e20 ms minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Interface\u003c\/td\u003e\n\u003ctd\u003e1 x RS-485 serial port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Location\u003c\/td\u003e\n\u003ctd\u003eLeftmost dedicated slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693PWR321T\u003c\/strong\u003e manages cross-backplane power delivery directly correlated with local I\/O density scaling. The hardware provides independent current paths to sustain the local CPU and auxiliary I\/O modules, preventing voltage sags during simultaneous point state updates. System deployment requires checking backplane firmware flash compatibility across connected modules to verify that cumulative current draw on the 5 VDC, 24 VDC Relay, and 24 VDC Isolated rails does not exceed the total 30 W combined limit. The local RS-485 serial interface provides physical layer communications for programming devices or operator interfaces attached directly to the chassis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this power supply unit operate concurrently in a hot-swap or redundant configuration?\u003c\/strong\u003e A: No. The unit does not support hot-swapping or parallel redundant configurations. De-energize the main line voltage before module replacement to avoid arcing on the backplane connector pins and subsequent system shutdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the power supply handle brief voltage interruptions on the incoming line?\u003c\/strong\u003e A: The module contains internal capacitor storage providing a minimum holdup time of 20 ms. If line voltage drops below specification for longer than 20 ms, the supply drops its outputs, triggering a CPU system halt to prevent unpredictable logic states.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Mounting:\u003c\/strong\u003e Mount the unit exclusively in the leftmost slot of the Series 90-30 baseplate. Slide the module down along the plastic guides until the rear connector seats firmly into the backplane receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Terminal Wiring:\u003c\/strong\u003e Wire incoming AC or DC power using standard industrial copper conductors. Ensure line, neutral, and ground wires are secured under the terminal screw clamps to prevent intermittent power loss under mechanical vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Noise Mitigation:\u003c\/strong\u003e Ground the baseplate chassis directly to the enclosure backpanel. Route all field I\/O cables away from the power supply input lines to suppress electromagnetic noise transmission into the internal 5 VDC logic bus.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44258833072227,"sku":"IC693PWR321T","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/34._8102b824-6969-484e-a384-6d6725dbc343.jpg?v=1781490484","url":"https:\/\/www.autocontrolglobal.com\/products\/ic693pwr321t-ge-fanuc-series-90-30-datasheet-technical-manual","provider":"AutoControl Global","version":"1.0","type":"link"}