{"product_id":"ic693pwr330h-ge-fanuc-series-90-30-high-capacity-power-supply","title":"IC693PWR330H GE Fanuc Series 90-30 High-Capacity Power Supply","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC693PWR330H operates as the primary high-capacity power supply engine for the Series 90-30 PLC chassis framework. This vital hardware module mounts directly onto the leftmost slot of the baseplate to convert incoming utility-grade AC or industrial DC voltages into regulated, clean electrical rails. It supplies 30 Watts of total output power, driving the local CPU card, distributed I\/O modules, and advanced communication modules across the backplane bus. Manufacturing plants, municipal water treatment facilities, and process industries deploy this specific module to maintain steady, ripple-free voltage levels and ensure continuous operation of complex PLC configurations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis 100% brand new, original GE Fanuc Series 90-30 hardware component delivers pristine out-of-the-box system regulation. All data points utilize standard ASCII formatting.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Revision Code:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIC693PWR330H\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBase Part Infrastructure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIC693PWR330\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeries 90-30 PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-Capacity System Power Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Input Ratings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120 \/ 240 VAC or 125 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAC Input Voltage Operational Envelope:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e85 to 264 VAC (Auto-sensing, 50 \/ 60 Hz frequency)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Input Voltage Operational Envelope:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 to 300 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power Consumption Thresholds:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e90 VA maximum with VAC input \/ 50 W maximum with VDC input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePeak Inrush Current Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4A peak maximum for a duration of 250 milliseconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Voltage Rails Provided:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e+5 VDC logic bus, 24 VDC Relay bus, 24 VDC Isolated field bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e5 VDC Output Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.0 VDC to 5.2 VDC (5.1 VDC nominal), delivering up to 30 Watts maximum (approx. 6A to 8A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC Relay Output Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 to 28 VDC, delivering up to 15 Watts maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC Isolated Output Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e21.5 VDC to 28 VDC, delivering up to 20 Watts maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Holdup Time Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 milliseconds minimum duration during source voltage dip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnboard Communication Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS-485 serial infrastructure via power supply port (supports SNP protocol)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Electrical Terminals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6 robust compression screw connection terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-In Protective Barriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 VDC overvoltage protection, overcurrent limiting, and thermal shutdown tracking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Temperature Envelope:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to +60 degrees Celsius\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature Envelope:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40 to +85 degrees Celsius\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity Limits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% non-condensing relative humidity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Hardware Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.25 lbs (0.57 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Box Shipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.0 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnifies Multi-Source Infrastructures with Auto-Sensing Input Regulators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial installations frequently face varying power grids, alternating between 120VAC utility taps, 240VAC field feeds, or 125VDC heavy-duty battery banks. The IC693PWR330H completely eliminates the need for manual jumper settings or multi-model stocking by integrating an auto-sensing input framework. The internal regulation circuit shifts automatically to handle anywhere from 85 to 264 VAC or 100 to 300 VDC, preventing component burnout from human wiring configuration mistakes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBypasses Voltage Transients via a 20ms Holdup Safeguard:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHeavy motor startups, localized short circuits, and utility grid switches create momentary line sags that can cause standard control systems to reset, stopping production lines. The IC693PWR330H incorporates a premium internal capacitor bank that guarantees a minimum 20-millisecond holdup time. This stored energy layout bridges brief source voltage drops, keeping the Series 90-30 CPU processing without dropping its execution loop or dropping communication links.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolates Field Feedback Loops through Dual 24VDC Bus Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInductive kickback from field relays and line noise from digital output loops can easily bleed back into controller cards, leading to logic corruption or damaged backplane data gates. The IC693PWR330H generates completely independent 24 VDC Relay and 24 VDC Isolated field power rails alongside its main 5 VDC logic bus. This physical electrical separation keeps noisy actuator lines completely isolated from the delicate logic processing circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHalts Electrical Damage using Overvoltage and Overcurrent Crowbars:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExternal wiring errors, shorted sensor lines, or field component decay can draw excessive current, threatening to cook the entire PLC rack. The IC693PWR330H integrates responsive overvoltage and overcurrent protective clamping barriers. If a field fault occurs, the module activates its internal protective limits instantly to shut down the output rails, confining the failure to the source wire and shielding your expensive I\/O modules from destruction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e: Is this IC693PWR330H power supply module completely brand new, and how do you guarantee its authenticity?\u003c\/strong\u003eA: Yes. We supply this power module strictly as a 100% brand new, original, and authentic factory-fresh item enclosed in its original, unopened GE Fanuc manufacturer packaging. Every unit contains pristine terminal contacts, factory-stamped serial numbering, and includes our full 12-month comprehensive warranty to ensure complete operational security.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e: What is the main difference between the standard power supply models and this \"H\" suffix high-capacity module?\u003c\/strong\u003eA: The \"H\" suffix (e.g., IC693PWR330H) represents the highest performance evolution of the 30W power supply family, featuring upgraded internal heat dissipation metrics and enhanced electronic component tolerances. It drops directly into any standard Series 90-30 backplane slot, replacing older hardware revisions (like the -AA, -CA, or -LT series) to deliver stable power to dense, high-point discrete and analog configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e: Can I use the built-in RS-485 serial port on the faceplate of this power supply to connect an HMI panel?\u003c\/strong\u003eA: Yes. The 6-pin serial port on the front face of the IC693PWR330H interfaces directly with the internal serial bus of the Series 90-30 backplane. It supports standard SNP and SNPx communication protocols, allowing you to plug in a local operator interface terminal, handheld programmer, or data log computing node without occupying a dedicated communication module slot on the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44196709826659,"sku":"IC693PWR330H","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/571_18060755-7289-4548-b6c5-7df287040d8f.jpg?v=1779350796","url":"https:\/\/www.autocontrolglobal.com\/products\/ic693pwr330h-ge-fanuc-series-90-30-high-capacity-power-supply","provider":"AutoControl Global","version":"1.0","type":"link"}