{"product_id":"ic694acc310a-ge-fanuc-pacsystems-rx3i-datasheet-manual","title":"IC694ACC310A GE Fanuc PACSystems RX3i Datasheet \u0026 Manual","description":"\u003ch2\u003eGE Fanuc IC694ACC310A Blank Slot Filler Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694ACC310A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC694ACC310\u003c\/strong\u003e Blank Slot Filler Module, operates as a dedicated hardware component for slot insulation and mechanical stabilization within PACSystems RX3i baseplate assemblies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694ACC310A \/ IC694ACC310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (Emerson Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg (0.25 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e135.0 mm x 38.0 mm x 127.0 mm (5.3 in x 1.5 in x 5.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNone (0.0 A backplane current draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eBlank slot filler module \/ Slot cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Line\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Baseplates\u003c\/td\u003e\n\u003ctd\u003e7, 12, and 16-slot standard baseplates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Expansion\u003c\/td\u003e\n\u003ctd\u003e5 and 10-slot expansion \/ remote baseplates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Count\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LED Indicators\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot-Swap Function\u003c\/td\u003e\n\u003ctd\u003eRemoval and insertion under power is allowed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructural Protections\u003c\/td\u003e\n\u003ctd\u003eVibration prevention and environmental debris shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Protective Shielding\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694ACC310A\u003c\/strong\u003e requires zero active processing resources and does not alter the backplane bus communication velocity of adjacent modules. The physical housing installs into any unused single-slot opening to maintain the structural continuity of the PACSystems RX3i chassis. By blocking exposed backplane connector traces, the module serves as an environmental shield that blocks conductive particulate matter and reduces fluid ingress hazards. This passive configuration supports unrestricted I\/O density scaling across remote or main multi-slot racks without requiring internal firmware flash compatibility updates or programming allocations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are there any specific firmware configurations or software addressing steps needed when adding this module to a live baseplate?\u003c\/strong\u003e A: No software programming or hardware configuration is required. The module contains no electronics or physical communication interfaces, meaning it does not register on the RX3i system I\/O map and remains transparent to the host CPU controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be physically inserted or extracted while the local chassis power supply is turned on?\u003c\/strong\u003e A: Yes. The module is fully rated for insertion and removal under power. Because it draws zero current from the +5 VDC or +24 VDC backplane rails, seating or removing the module will not cause electrical arcing, current spikes, or data disruptions on the active parallel bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Slot Engagement:\u003c\/strong\u003e Align the top and bottom structural tabs of the filler module with the plastic card guides of the chosen empty slot on the RX3i baseplate. Push the module firmly inward until the mechanical locking latch engages securely with the chassis frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Ingress Mitigation:\u003c\/strong\u003e Install these filler units in all unpopulated slots within the rack assembly. This practice ensures that internal airflow patterns remain optimized for thermal heat dissipation across nearby processing or power modules and keeps airborne dust off open backplane pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Stabilizing Procedures:\u003c\/strong\u003e Verify that the captive fasteners or integrated plastic clips are completely secured against the sheet metal rail. Proper engagement prevents mechanical vibration from creating resonant noise inside high-density control enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44258824814691,"sku":"IC694ACC310A","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/68_704970a5-c7d1-4d00-85e4-49bda32802e7.jpg?v=1781487221","url":"https:\/\/www.autocontrolglobal.com\/products\/ic694acc310a-ge-fanuc-pacsystems-rx3i-datasheet-manual","provider":"AutoControl Global","version":"1.0","type":"link"}