{"product_id":"ic694dsm324-be-ge-fanuc-motion-controller-rx3i-module","title":"IC694DSM324-BE GE Fanuc Motion Controller RX3i Module","description":"\u003ch2\u003eGE Fanuc IC694DSM324-BE PACSystems RX3i 4-Axis Motion Controller Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for multi-axis servo position and velocity execution in PACSystems RX3i platforms, the \u003cstrong\u003eGE Fanuc IC694DSM324-BE\u003c\/strong\u003e (\u003cstrong\u003eIC694DSM324\u003c\/strong\u003e Motion Controller Module) provides direct physical\/electrical execution across high-speed industrial processing lines.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Hardware Variant\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSubsystem Revision\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Topology\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC694DSM324\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-BE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware Revision B, Edition E\u003c\/td\u003e\n\u003ctd\u003eFSSB Fiber Optic \/ 36-Pin D-Shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694DSM324-BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 kg (0.69 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e168 x 150 x 55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e860 mA at 5 VDC (Backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControlled Axes\u003c\/td\u003e\n\u003ctd\u003eUp to 4 independent or synchronized axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003eStandard Mode (follower loop disabled), Follower Mode (loop enabled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotion Profile Types\u003c\/td\u003e\n\u003ctd\u003eElectronic CAM, Position Control, Velocity Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-Board Program Memory\u003c\/td\u003e\n\u003ctd\u003eFlash storage for 10 programs and 40 subroutines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eServo Interface\u003c\/td\u003e\n\u003ctd\u003eFSSB Fiber Optic Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary I\/O Connectors\u003c\/td\u003e\n\u003ctd\u003eDual 36-pin D-shell connectors (24 VDC I\/O and 5 VDC I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial\/Network Interfaces\u003c\/td\u003e\n\u003ctd\u003eRS232, RS485, Modbus, Ethernet, RJ-45 COMM port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Encoder Power Output\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Resolution\u003c\/td\u003e\n\u003ctd\u003e13 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlock Processing Time\u003c\/td\u003e\n\u003ctd\u003eLess than 5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Display\u003c\/td\u003e\n\u003ctd\u003e8 LED Status Indicators (STATUS, OK, CONFIG, FSSB, AXIS 1-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Slot Usage\u003c\/td\u003e\n\u003ctd\u003eSingle Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Motion \u0026amp; Deterministic Network Features\u003c\/h3\u003e\n\u003cp\u003eThe module handles backplane bus communication velocity and deterministic real-time execution via the PACSystems RX3i backplane interface. Servo command distribution relies on the Fiber Servo Serial Bus (FSSB) optoelectronic link, isolating noise while sending motion profiles to downstream servo drives. Non-volatile flash storage maintains electronic CAM tables locally to avoid backplane execution latencies during synchronized high-speed operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane power budget restrictions when adding external encoders to the IC694DSM324-BE?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a nominal 860 mA at 5 VDC from the RX3i backplane bus. When utilizing external 5 VDC incremental encoders, an additional power draw up to 500 mA occurs on the 5 VDC supply bus, requiring total backplane load validation prior to installation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC694DSM324-BE module be replaced while the PACSystems RX3i system remains powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping (Hot Swap \/ Insertion and Removal Under Power) within RX3i universal backplanes. However, external 24 VDC auxiliary field wiring and FSSB fiber connections must be disconnected prior to releasing the module retaining mechanisms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain panel grounding resistance at or below 100 ohm connected directly to the primary enclosure ground bus bar.\u003c\/li\u003e\n\u003cli\u003eSecure all 36-pin D-shell I\/O connections using integrated screw locks to prevent interface degradation in high-vibration environments.\u003c\/li\u003e\n\u003cli\u003eRoute FSSB fiber optic cables outside of high-voltage wire trunks, maintaining minimum bend radius thresholds to prevent optical signal loss.\u003c\/li\u003e\n\u003cli\u003eVerify CPU firmware release compatibility (RX3i CPU firmware v2.80 or later and DSM324i firmware v1.61 or later) prior to system commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44437591785571,"sku":"IC694DSM324-BE","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/432_162b3d73-3188-431c-8b7f-316201a9475d.jpg?v=1785829160","url":"https:\/\/www.autocontrolglobal.com\/products\/ic694dsm324-be-ge-fanuc-motion-controller-rx3i-module","provider":"AutoControl Global","version":"1.0","type":"link"}