IC694MDL660CA-BC GE Fanuc PACSystems RX3i Datasheet & Technical Manual
IC694MDL660CA-BC GE Fanuc PACSystems RX3i Datasheet & Technical Manual
IC694MDL660CA-BC GE Fanuc PACSystems RX3i Datasheet & Technical Manual
/ 3

IC694MDL660CA-BC GE Fanuc PACSystems RX3i Datasheet & Technical Manual

  • Manufacturer: GE Fanuc

  • Part Number: IC694MDL660CA-BC

  • Condition:New with Original Package

  • Product Type: Digital Output Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE Fanuc IC694MDL660CA-BC PACSystems RX3i Series

The GE Fanuc IC694MDL660CA-BC, also cataloged as the GE Fanuc IC694MDL660 Digital Output Module, operates as a dedicated hardware component for field device execution within PACSystems RX3i platform networks.

Hardware Specifications

Parameter Specification
Model IC694MDL660CA-BC
Brand GE Fanuc
Origin United States
Weight 0.2 kg (0 lbs 8.0 oz)
Dimensions 3.8 cm x 14.0 cm x 14.0 cm (1.5 in x 5.5 in x 5.5 in)
Operating Temp 0 to +60 deg C
Power Consumption 130 mA (from backplane logic side)
Output Type Positive logic DC output
Number of Points 32 outputs
Rated Voltage 12/24 VDC
Voltage Range 12-24 VDC (+20%, -15%)
Output Current 0.5 A per point (continuous), 4.0 A max per group at 50 deg C
ON Voltage Drop <= 1.2 V DC
OFF Leakage Current <= 1 mA
Response Time ON <= 2 ms, OFF <= 2 ms
Protection Electronic short-circuit protection (per group)
Isolation 1500 VAC field-to-logic, 500 VAC between groups
Storage Temperature -20 to +70 deg C
Humidity 5-95% RH, non-condensing
Certifications UL, CE, CSA compliant

Industrial Control and Drives Logic Synchronization

The 32-point sourcing card interfaces directly with the host chassis assembly, resolving state adjustments to scale real-time I/O density scaling requirements. The hardware aligns with the standard backplane bus communication velocity Licences to transmit state data under 2 ms processing windows. This digital block implements strict electronic short-circuit monitoring per group, validating electrical boundaries independently of active firmware flash compatibility processes. Built-in discrete filters work in tandem with regional data paths to sustain Profinet / EtherNet/IP deterministic networks, absorbing line disturbances while protecting internal logic arrays from inductive kickback.

Frequently Asked Questions

Q: What are the backplane current constraints and loading limits when setting up multiple 32-point output modules?

A: The card draws 130 mA from the internal logic bus. When populating high-density racks, engineers must calculate cumulative milliamp draw values to prevent over-loading the chassis power supply module.

Q: Is this digital output module hot-swap compatible within the PACSystems RX3i rack platform?

A: Yes, the module supports hot-swap physical insertion and extraction within active RX3i chassis slots. However, removing a module while running breaks active field loops instantly, which can trigger downline interlock faults across the broader industrial network.

Field Installation Guidelines

  • Chassis Engagement and Alignment: Align the top and bottom hooks of the module with the chosen RX3i slot guides. Swing the module down firmly into the backplane connectors until the top latch engages completely, then tighten the retaining screws.
  • Field Wiring and Group Isolation: Wire the 32 outputs across the 4 independent groups of 8 points each. Verify that external 12/24 VDC power supplies comply with the specified +20% / -15% voltage bounds to preserve nominal switching levels.
  • Shield Grounding and Cable Separation: Group all DC field lines inside separate wire ways away from high-voltage AC lines or motor driver circuits. Connect external cable shields to the primary enclosure ground rail to prevent induced noise spikes on the signal lines.