{"product_id":"ic695cru320-el-ge-pacsystems-rx3i-redundant-processor","title":"IC695CRU320-EL GE PACSystems RX3i Redundant Processor","description":"\u003ch2\u003eGE IC695CRU320-EL PACSystems RX3i Redundant CPU Controller\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-reliability hot standby redundant control in industrial processes, the \u003cstrong\u003eGE IC695CRU320-EL\u003c\/strong\u003e (\u003cstrong\u003eIC695CRU320\u003c\/strong\u003e Redundancy Control Processor Module) provides direct physical\/electrical execution across PACSystems RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695CRU320-EL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (GE Fanuc \/ Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e166 mm x 47 mm x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e25 W (125 VDC typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e32 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory\u003c\/td\u003e\n\u003ctd\u003e16 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Speed\u003c\/td\u003e\n\u003ctd\u003e1.5 us per Boolean instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 (installed in compliant cabinet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 x RS-232, 1 x Ethernet (10\/100 Mbps RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Ethernet Communication \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe GE IC695CRU320-EL interfaces directly with the PACSystems RX3i high-speed backplane bus to deliver synchronized state replication between primary and backup rack configurations. Integrated 10\/100 Mbps Ethernet communication maintains deterministic data exchanges for HMI, SCADA, and peer-to-peer network nodes without delaying critical logic scan cycles. System firmware flash compatibility allows seamless updates while preserving user program memory and data register configurations across cold restart sequences.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the IC695CRU320-EL maintain failover synchronization with the backup unit?\u003c\/p\u003e\n\u003cp\u003eA: The processor transfers memory state data over dedicated redundancy links across the backplane, permitting immediate switchover to the standby CPU upon primary fault detection.\u003c\/p\u003e\n\u003cp\u003eQ: What is the power consumption requirement for backplane planning?\u003c\/p\u003e\n\u003cp\u003eA: The module draws approximately 25 W from the RX3i backplane power supply operating at a nominal 125 VDC input level.\u003c\/p\u003e\n\u003cp\u003eQ: How should the RS-232 communication line be wired to prevent noise interference?\u003c\/p\u003e\n\u003cp\u003eA: Utilize low-capacitance shielded serial cables with the shield braid grounded at the primary panel earth point, ensuring cable runs do not parallel high-voltage AC power lines.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the CPU directly into the designated controller slot of an IP20-compliant PACSystems RX3i backplane rack. Verify that ambient operating temperatures stay strictly within 0 deg C to +60 deg C and relative humidity remains non-condensing. Secure all rack mounting fasteners to prevent vibration-induced dislodgement from the backplane bus socket.\u003c\/p\u003e\n\u003cp\u003eEstablish chassis grounding by bonding the main enclosure ground bar directly to system earth using a low-impedance copper strap. When connecting Ethernet cables to the front RJ45 port, maintain industrial Category 5e shielding and keep wiring routed away from high-power drive outputs or motor control conductors to preserve deterministic Ethernet data integrity.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43820703776867,"sku":"IC695CRU320-EL","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/144_75c1479d-4a30-4ae2-9b45-b71e3d6c5e63.jpg?v=1762420399","url":"https:\/\/www.autocontrolglobal.com\/products\/ic695cru320-el-ge-pacsystems-rx3i-redundant-processor","provider":"AutoControl Global","version":"1.0","type":"link"}