GE Fanuc IC695PSA040F PACSystems RX3i Power Supply Module
The GE Fanuc IC695PSA040F, also cataloged as the IC695PSA040 Standard AC Power Supply Module, operates as a dedicated hardware component for converting 120/240 VAC or 125 VDC input into regulated voltage rails within PACSystems RX3i PLC networks.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IC695PSA040F (Base Model: IC695PSA040) |
| Brand | GE Fanuc |
| Origin | USA |
| Weight | 2.0 kg (4.4 lbs) |
| Dimensions | Standard single-slot module for RX3i universal backplane |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | Input Power: 40 W maximum |
| Input Voltage Range, AC | 85 to 264 VAC (120/240 VAC nominal, 50/60 Hz) |
| Input Voltage Range, DC | 100 to 300 VDC (125 VDC nominal) |
| Output Voltage | +5.1 VDC (4 A max), +24 VDC Relay (1 A max), +24 VDC Isolated (15 W max) |
| Total Output Power | 40 W total maximum capacity |
| Protection | Overvoltage, overcurrent, and short-circuit protection |
| Mounting Location | Leftmost slot of RX3i baseplate |
| Fuse Type | Field-replaceable |
| Certifications | CE compliant, UL listed, CSA approved |
Backplane Power Routing and Density Scaling
The IC695PSA040F regulates direct current pathways over the universal RX3i backplane bus channels, supplying up to 4 A on the primary logical +5.1 VDC line. The physical arrangement provides localized power routing for small to medium I/O density scaling, sustaining both the internal processing architectures and peripheral interface loops. To ensure firmware flash compatibility routines execute without power-loss corruption, the internal circuit utilizes diagnostic tracking coupled to front-panel "OK" and "FAULT" status indicators that monitor the stability of the isolated 21.5 to 28 VDC and relay 24 to 28 VDC supply paths.
Frequently Asked Questions
Q: What physical response occurs when the short-circuit protection trips on the +5.1 VDC rail?
A: The module executes an immediate electronic shutdown of the output voltage rails to isolate the backplane logic from thermal overload. The front-panel "FAULT" LED illuminates, and the system halts control execution until the external short circuit is resolved and input power is cycled.
Q: Can the IC695PSA040F power supply module be used in a parallel redundancy configuration?
A: No. The internal electrical execution of this module does not support load sharing or parallel bus synchronization. It must be installed as a standalone power source within the dedicated leftmost slot of the RX3i rack frame.
Q: Is this module compatible with pure DC input distribution networks?
A: Yes. Despite being designated primarily as an AC supply, the internal rectification hardware accepts a nominal 125 VDC input voltage source across a continuous physical operating range of 100 to 300 VDC.
Field Installation Guidelines
- Chassis Allocation Restriction: Position and lock the module strictly within the leftmost slot of the RX3i baseplate. Attempting insertion into standard I/O option slots will damage the rear multi-pin backplane connector.
- Grounding Requirements: Wire a low-impedance earth conductor from the terminal block ground screw directly to the enclosure ground bus bar to suppress high-frequency electrical noise.
- Convection Cooling Clearances: Ensure an unobstructed boundary of at least 50 mm (2 inches) above, below, and in front of the power supply housing to allow natural convection currents to match the internal thermal dissipation profiles.
- Terminal Strip Segregation: Maintain physical separation between the incoming 120/240 VAC mains supply wires and nearby low-voltage analog or digital communication lines within the panel tracking to minimize capacitive cross-talk.