{"product_id":"ic695psd040b-ge-pacsystems-rx3i-power-supply-module-40w","title":"IC695PSD040B GE PACSystems RX3i Power Supply Module 40W","description":"\u003ch2\u003eGE IC695PSD040B PACSystems RX3i Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-efficiency DC power delivery in PACSystems RX3i backplane racks, the \u003cstrong\u003eGE IC695PSD040B\u003c\/strong\u003e (\u003cstrong\u003eIC695PSD040\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution. This hardware unit generates regulated internal bus voltages from an AC line input to sustain logic processing, I\/O bus communications, and field-side relay drive loops across local and expansion rack setups.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IC695PSD040B\u003c\/strong\u003e designation details specific firmware revision increments, component updates, and hardware backplane compatibility characteristics within the GE \/ Emerson PACSystems RX3i platform.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eRevision Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eBackplane Footprint\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC695PSD040\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eInitial release 40 W AC power supply module\u003c\/td\u003e\n\u003ctd\u003eSingle-slot universal rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC695PSD040\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eEnhanced circuit protection and component thermal tolerances\u003c\/td\u003e\n\u003ctd\u003eSingle-slot universal rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695PSD040B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric) \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (0.66 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.3 cm x 14.0 cm x 13.5 cm (1.3 in x 5.5 in x 5.3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e40 W maximum output capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC (47-63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Input Range\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Output Capability\u003c\/td\u003e\n\u003ctd\u003e+5 VDC at 4 A; +3.3 VDC at 3 A; +24 VDC relay bus at 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC input-to-output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Efficiency\u003c\/td\u003e\n\u003ctd\u003eApproximately 70% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicator\u003c\/td\u003e\n\u003ctd\u003eFront panel Power OK LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Protection\u003c\/td\u003e\n\u003ctd\u003eOvervoltage, overcurrent, thermal shutdown circuitry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, CE, CSA, ATEX Zone 2, Class I Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Power Allocation Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSD040B delivers triple-voltage DC rails directly to the PACSystems RX3i backplane bus. Internal power conditioning circuits convert incoming 85-264 VAC supply lines into high-density +5 VDC (4 A) and +3.3 VDC (3 A) logic supplies alongside a localized +24 VDC (0.5 A) isolated relay bus. System configuration software verifies total backplane current draw prior to deployment to prevent voltage drop across high-density digital I\/O arrays. Thermal dissipation profiles remain optimized through internal heatsink conduction, ensuring system firmware stability across deterministic Ethernet and backplane communication paths without active fan cooling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC695PSD040B power supply module be hot-swapped during rack operation?\u003c\/p\u003e\n\u003cp\u003eA: No. Installing or removing the IC695PSD040B while the AC main power line is energized causes electric arc risk and disrupts the backplane logic bus. Power down all incoming 120\/240 VAC supply lines before insertion or extraction.\u003c\/p\u003e\n\u003cp\u003eQ: What limits apply to the +24 VDC output bus provided by this module?\u003c\/p\u003e\n\u003cp\u003eA: The onboard +24 VDC relay bus supplies a maximum current of 0.5 A. External power supplies must drive field actuators or heavy relay loads exceeding this threshold to avoid triggering internal thermal shutdown or overcurrent protection circuits.\u003c\/p\u003e\n\u003cp\u003eQ: Is it permissible to parallel two IC695PSD040B modules in a single RX3i backplane for power redundancy?\u003c\/p\u003e\n\u003cp\u003eA: No. The standard RX3i universal backplane supports only one power supply module per rack section. Load expansion requires an additional expansion backplane populated with its own dedicated power supply unit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMounting and wiring of the IC695PSD040B must occur in de-energized conditions. Seat the module firmly into the dedicated power supply slot on the far left of the RX3i universal backplane until the rear connector latches engage fully. Fasten the captive retaining screw at the top of the module to guarantee physical grounding through the DIN-rail \/ panel chassis backplate.\u003c\/p\u003e\n\u003cp\u003eIncoming 120\/240 VAC supply conductors must pass through dedicated terminal block screws. Maintain a physical separation of at least 50 mm between AC power input cables and low-voltage DC I\/O signal lines to limit high-frequency electromagnetic noise coupling. Strip conductor insulation strictly to manufacturer length specifications to avoid bare wire exposure. Connect the protective earth (PE) terminal directly to the central cabinet ground busbar using a low-impedance conductor with a minimum engagement torque compliant with standard panel assembly practices.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44464747446371,"sku":"IC695PSD040B","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/498._dcc9553f-c9c6-4ff0-a4d4-806aaf76a073.jpg?v=1786434297","url":"https:\/\/www.autocontrolglobal.com\/products\/ic695psd040b-ge-pacsystems-rx3i-power-supply-module-40w","provider":"AutoControl Global","version":"1.0","type":"link"}