IC695PSD040F GE Fanuc RX3i Power Supply Module
Manufacturer: GE Fanuc
-
Part Number: IC695PSD040F
Condition:New with Original Package
Product Type: Power Supply Modules
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
GE Fanuc IC695PSD040F PACSystem RX3i Power Supply Module
The GE Fanuc IC695PSD040F, also cataloged as the IC695PSD040 power supply module, operates as a dedicated hardware component for converting 24 VDC input power into regulated backplane voltage within PACSystem RX3i chassis racks.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IC695PSD040F (Base Model: IC695PSD040) |
| Brand | GE Fanuc |
| Origin | China |
| Weight | 0.40 kg (0.88 lbs) |
| Dimensions | Standard RX3i Single-Slot Form Factor |
| Operating Temp | 0 deg C to 60 deg C |
| Power Consumption | Approx 1.0 A at 24 VDC input |
| Output Power | 40 W total regulated DC output |
| Output Voltage | +5 VDC (backplane bus power) |
| Output Current Capacity | Up to 8 A maximum |
| Input Voltage Range | 18 VDC to 30 VDC |
| Redundancy Support | Dual 24 VDC input power terminals |
| Built-In Protection | Overcurrent, overvoltage, and thermal shutdown |
| Isolation Barrier | 1500 V RMS between field input and backplane logic |
| Diagnostics | Status LEDs for Power OK, Fault, and Redundancy state |
| Relative Humidity | 5% to 95% RH, non-condensing |
Deterministic Backplane & Power Distribution Execution
Engineers integrate the GE Fanuc IC695PSD040F module into dedicated power supply slots on the RX3i backplane bus to ensure stable logic rails across high-density I/O arrays. The module regulates incoming 24 VDC power to maintain continuous voltage stability without impacting backplane bus communication velocity during peak current transients. Internal protection circuits coordinate fault reporting with the primary CPU to preserve firmware flash compatibility and maintain system operation across deterministic EtherNet/IP networks.
Frequently Asked Questions
Q: Does the module support parallel power sharing across dual input feeds?
A: The module accepts two independent 24 VDC input supplies to provide redundant power rail switching, automatically maintaining +5 VDC backplane output if one primary DC source fails.
Q: How does the power supply handle internal overtemperature conditions?
A: The hardware incorporates thermal shutdown circuitry that safely disables output current delivery when internal component temperatures exceed thermal limits, asserting the front-panel Fault LED.
Field Installation Guidelines
Technicians must install the module into the dedicated power supply slot on the PACSystem RX3i baseplate before powering up the system. Wiring to the 24 VDC input terminals must use copper conductors rated for at least 75 deg C, with wire gauges sized to limit line voltage drops below the 18 VDC minimum operating threshold under full 40 W load. Installers must route DC power supply lines separately from high-voltage AC circuits and connect the chassis ground lug directly to a central enclosure grounding bar using low-impedance copper grounding straps.