{"product_id":"ic695psd040f-ge-fanuc-rx3i-power-supply-module","title":"IC695PSD040F GE Fanuc RX3i Power Supply Module","description":"\u003ch2\u003eGE Fanuc IC695PSD040F PACSystem RX3i Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695PSD040F\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695PSD040\u003c\/strong\u003e power supply module, operates as a dedicated hardware component for converting 24 VDC input power into regulated backplane voltage within PACSystem RX3i chassis racks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695PSD040F (Base Model: IC695PSD040)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.40 kg (0.88 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard RX3i Single-Slot Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox 1.0 A at 24 VDC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e40 W total regulated DC output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e+5 VDC (backplane bus power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 VDC to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual 24 VDC input power terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-In Protection\u003c\/td\u003e\n\u003ctd\u003eOvercurrent, overvoltage, and thermal shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Barrier\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS between field input and backplane logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eStatus LEDs for Power OK, Fault, and Redundancy state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane \u0026amp; Power Distribution Execution\u003c\/h3\u003e\n\u003cp\u003eEngineers integrate the \u003cstrong\u003eGE Fanuc IC695PSD040F\u003c\/strong\u003e module into dedicated power supply slots on the RX3i backplane bus to ensure stable logic rails across high-density I\/O arrays. The module regulates incoming 24 VDC power to maintain continuous voltage stability without impacting backplane bus communication velocity during peak current transients. Internal protection circuits coordinate fault reporting with the primary CPU to preserve firmware flash compatibility and maintain system operation across deterministic EtherNet\/IP networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support parallel power sharing across dual input feeds?\u003c\/p\u003e\n\u003cp\u003eA: The module accepts two independent 24 VDC input supplies to provide redundant power rail switching, automatically maintaining +5 VDC backplane output if one primary DC source fails.\u003c\/p\u003e\n\u003cp\u003eQ: How does the power supply handle internal overtemperature conditions?\u003c\/p\u003e\n\u003cp\u003eA: The hardware incorporates thermal shutdown circuitry that safely disables output current delivery when internal component temperatures exceed thermal limits, asserting the front-panel Fault LED.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTechnicians must install the module into the dedicated power supply slot on the PACSystem RX3i baseplate before powering up the system. Wiring to the 24 VDC input terminals must use copper conductors rated for at least 75 deg C, with wire gauges sized to limit line voltage drops below the 18 VDC minimum operating threshold under full 40 W load. Installers must route DC power supply lines separately from high-voltage AC circuits and connect the chassis ground lug directly to a central enclosure grounding bar using low-impedance copper grounding straps.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44469854601315,"sku":"IC695PSD040F","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/506_7f862ecf-ce5f-4211-b1aa-6b739d91f529.jpg?v=1786518639","url":"https:\/\/www.autocontrolglobal.com\/products\/ic695psd040f-ge-fanuc-rx3i-power-supply-module","provider":"AutoControl Global","version":"1.0","type":"link"}