{"product_id":"ic697bem713-ge-fanuc-series-90-70-datasheet-technical-manual","title":"IC697BEM713 GE Fanuc Series 90-70 Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eGE Fanuc IC697BEM713 Bus Transmitter Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC697BEM713E\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC697BEM713\u003c\/strong\u003e Bus Transmitter Module, operates as a dedicated hardware component for multi-rack system expansion within GE Fanuc Series 90-70 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697BEM713E \/ IC697BEM713F \/ IC697BEM713G \/ IC697BEM713\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.94 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 90-70 single-slot module dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.0 W (1.4 A @ 5 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eBus Transmitter Module (BTM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eSeries 90-70 PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 7 additional IC697 expansion racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffective Data Rate\u003c\/td\u003e\n\u003ctd\u003e500 Kbytes\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Distance\u003c\/td\u003e\n\u003ctd\u003e50 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eNon-isolated differential communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e1 x Top Programmer Port, 1 x Bottom Expansion Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e3 x Diagnostic LEDs (MODULE OK, PGMR, EXPANSION PORT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eSoftware-defined (no hardware DIP switches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC697BEM713\u003c\/strong\u003e utilizes a high-speed parallel bus interface operating across the standard Series 90-70 backplane. It coordinates data packet routing to external expansion racks via non-isolated differential communication lines at an effective data rate of 500 Kbytes\/sec. System integration requires precise synchronization between the host CPU firmware flash compatibility parameters and the hardware revision of the Bus Receiver Modules (BRMs) connected in the downstream daisy-chain. Backplane bus communication velocity remains stable under maximum I\/O density scaling up to the 7-rack system boundary limit.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be hot-swapped while the local backplane is energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The backplane power supply must be completely turned off before inserting or extracting the module. Live insertion or extraction will cause severe disruptions on the VME parallel bus, resulting in data corruption, unexpected CPU faults, or physical damage to the module circuitry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require physical jumper changes or DIP switch settings during commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No physical DIP switches or jumpers exist on the circuit board. All configuration and rack allocation maps are defined via MS-DOS or Windows-based programming software, which pushes configuration files directly to the module upon CPU synchronization.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Allocation Restrictions:\u003c\/strong\u003e Do not install this module in Slot 1 of the rack, which is reserved exclusively for the CPU. The module must be positioned in a standard I\/O slot located to the right of any hardware interrupt source modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding Protocols:\u003c\/strong\u003e Connect expansion cables tightly to the designated top and bottom connectors. Ensure that the integrated cable shielding maintains structural integrity across the maximum allowable 50-foot run to suppress electrical noise and signal attenuation on the differential lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Status Verification Sequence:\u003c\/strong\u003e Upon system startup, confirm that the top MODULE OK LED remains illuminated. A blinking or dark LED indicates that the host CPU has failed to verify the module configuration or that one of the downstream expansion racks has timed out during the parallel bus poll sequence.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44258821079139,"sku":"IC697BEN713G","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/63._98e72fb3-29a2-4de9-8e31-5df20567495a.jpg?v=1781485768","url":"https:\/\/www.autocontrolglobal.com\/products\/ic697bem713-ge-fanuc-series-90-70-datasheet-technical-manual","provider":"AutoControl Global","version":"1.0","type":"link"}