{"product_id":"ic697chs790g-ge-fanuc-series-90-70-9-slot-plc-rack-chassis","title":"IC697CHS790G GE Fanuc Series 90-70 9-Slot PLC Rack Chassis","description":"\u003ch2\u003eGE Fanuc IC697CHS790G Series 90-70 9-Slot Rack\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC697CHS790G\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC697CHS790\u003c\/strong\u003e 9-Slot Rack, operates as a dedicated hardware component for module structural housing and backplane signal interconnection within Series 90-70 PLC platforms. This VME standard C.1 mechanical chassis provides physical mounting slots and backplane power distribution for power supply units, CPUs, and I\/O modules across a integrated backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697CHS790G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e14.69 lbs (6.66 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEnclosure depth 10.0 in (255 mm); 19.0 in standard rack panel width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.5 A current required from I\/O bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Slots\u003c\/td\u003e\n\u003ctd\u003e9 slots (plus dedicated power supply location)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Bus Standard\u003c\/td\u003e\n\u003ctd\u003eVME standard C.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum 5 VDC Current\u003c\/td\u003e\n\u003ctd\u003e20 A maximum (with 100 W power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd\u003eFront 19-inch rack mounting or rear panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack ID Configuration\u003c\/td\u003e\n\u003ctd\u003e4 jumpers located behind power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Extension Cable\u003c\/td\u003e\n\u003ctd\u003eIC697CBL700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBrand-Specific Hardware Architecture\u003c\/h3\u003e\n\u003cp\u003eThe backplane bus communication velocity across the Series 90-70 chassis complies with VME standard C.1 execution rules to maintain deterministic multi-card logic execution. The integrated backplane trace matrix delivers high-speed parallel signal routing between the CPU slot and peripheral I\/O cards while sustaining a maximum 20 A current capacity on the primary 5 VDC rail. Direct physical contact pin geometry limits trace noise and supports seamless firmware flash compatibility checks between processor modules and local expansion boards.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How do technicians configure the physical rack address when setting up multi-rack Series 90-70 expansion systems?\u003c\/p\u003e\n\u003cp\u003eA: System integrators set the rack identification number by configuring four hardware jumpers located directly behind the rack power supply module before powering up the backplane.\u003c\/p\u003e\n\u003cp\u003eQ: Can modules be inserted or extracted from the IC697CHS790G chassis while backplane power is active?\u003c\/p\u003e\n\u003cp\u003eA: No, field engineers must isolate primary input power from the power supply unit prior to inserting or removing IC697 modules to prevent bus contention errors and connector pin damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the IC697CHS790G rack securely into a standard 19-inch enclosure frame using front mounting flanges, or fasten it directly to an industrial enclosure backpanel using rear mounting points. Maintain a minimum vertical clearance of 3 inches above and below the chassis frame to ensure natural convection airflow across installed module heat sinks.\u003c\/p\u003e\n\u003cp\u003eEstablish a low-impedance ground connection by bonding the chassis frame ground lug to the main panel protective earth (PE) bus using a heavy-gauge copper strap. Ensure that all module retaining screws are fully torqued to maintain positive earth continuity and prevent card movement under high-vibration field conditions.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44486154256483,"sku":"IC697CHS790G","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/545._0623c298-e553-4e73-ae1b-7f45b6eef5c5.jpg?v=1787039670","url":"https:\/\/www.autocontrolglobal.com\/products\/ic697chs790g-ge-fanuc-series-90-70-9-slot-plc-rack-chassis","provider":"AutoControl Global","version":"1.0","type":"link"}