{"product_id":"irc5-safety-board-module-abb-dsqc626a-3hac026289-001","title":"IRC5 Safety Board Module | ABB DSQC626A 3HAC026289-001","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB DSQC626A (3HAC026289-001) serves as the primary safety supervisor for ABB industrial robots utilizing the IRC5 controller platform. This 100% brand new, original safety board module coordinates the Drive Enable\/Disable logic and monitors critical safety circuits, including emergency stop (E-stop) chains and gate interlocks. By acting as the hardware-level gatekeeper for the robotic drive system, the DSQC626A ensures that power reaches the motors only when all safety conditions are met. Its integration into the IRC5 backplane allows for instantaneous reaction to hazards, providing essential protection for both human operators and expensive downstream equipment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe DSQC626A utilizes high-reliability internal relays and logic to maintain safety integrity in high-speed manufacturing environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDSQC626A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3HAC026289-001\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB IRC5 Robot Controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE-stop monitoring, Drive Enable\/Disable, Safety Circuit Supervision\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafety relay connections via controller backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg – 0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e180 mm × 100 mm × 40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden \/ Finland\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe ABB DSQC626A 3HAC026289-001 addresses the rigorous demands of safety-critical robotic automation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware-Level Drive Supervision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module manages the physical \"Enable\" signal required by the drive units to power the robot motors. This hardware-based approach provides a layer of protection independent of the main CPU software, ensuring a safe state even during controller logic errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstantaneous Hazard Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDirect integration with the IRC5 backplane enables the DSQC626A to process E-stop signals with zero software latency. Upon receiving a fault or stop trigger, the module immediately breaks the drive enable circuit to halt all robotic motion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust EMC Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-frequency switching from drive units often generates significant electrical noise. ABB designs this module with industrial-grade EMC shielding to prevent nuisance tripping and ensure that safety signals remain clean and stable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Backplane Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact, rack-mountable design slides directly into the IRC5 controller chassis. This eliminates complex point-to-point wiring for safety relays, reducing the risk of wiring errors and simplifying the installation of redundant safety loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the DSQC626A require any software configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The DSQC626A functions as a hardware-level safety module. It interfaces directly with the IRC5 backplane and works in conjunction with the controller’s safety system parameters without requiring independent programming.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module to monitor external safety devices like light curtains?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can integrate light curtains, safety mats, and gate switches into the safety circuit that the DSQC626A supervises. When any of these external devices trigger, the module instantly disables the drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify if the board is functioning correctly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IRC5 controller monitors the health of the DSQC626A. Any internal relay failure or loss of signal integrity will trigger a \"Safety System Fault\" on the teach pendant, preventing the robot from entering a \"Motors On\" state until you resolve the issue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the DSQC626A compatible with older S4C+ controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3HAC026289-001 is specifically engineered for the IRC5 controller series. While it shares some functional traits with older DSQC safety modules, the physical interface and bus protocol target the modern IRC5 backplane architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43835344257123,"sku":"DSQC626A 3HAC026289-001","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/307.2_5cc4653d-34b7-40c2-95e2-833200772080.jpg?v=1776647541","url":"https:\/\/www.autocontrolglobal.com\/products\/irc5-safety-board-module-abb-dsqc626a-3hac026289-001","provider":"AutoControl Global","version":"1.0","type":"link"}