{"product_id":"is200acleh1bcd-ge-mark-vi-application-control-layer-module","title":"IS200ACLEH1BCD GE Mark VI Application Control Layer Module","description":"\u003ch2\u003eGeneral Electric IS200ACLEH1BCD Mark VI Application Control Layer Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-precision signal distribution and logic processing in Mark VI turbine control platforms, the \u003cstrong\u003eGeneral Electric IS200ACLEH1BCD\u003c\/strong\u003e (\u003cstrong\u003eIS200ACLE\u003c\/strong\u003e Application Control Layer Module) provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200\u003c\/strong\u003e: Standard Mark VI series system board prefix.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eACLE\u003c\/strong\u003e: Application Control Layer Expansion module function designator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eH1\u003c\/strong\u003e: Hardware base structure and connector pinout configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBCD\u003c\/strong\u003e: Specific revision revision code designating updated internal board revisions and component layouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ACLEH1BCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e267 mm x 216 mm x 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC from system backplane at 400 mA to 600 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e8 channels (0 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.2% full-scale at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Voltage Range\u003c\/td\u003e\n\u003ctd\u003e6 VDC to 30 VDC external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V between I\/O circuits and system backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Architecture \u0026amp; Deterministic Execution\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS200ACLEH1BCD\u003c\/strong\u003e interfaces directly with the proprietary Mark VI backplane bus, driving real-time data frame transfers between processor cards and field conditioning hardware. Onboard logic circuits execute deterministic signal distribution without latency spikes on internal bus segments.\u003c\/p\u003e\n\u003cp\u003eThe module incorporates firmware flash compatibility handshakes that verify card hardware code indices against central controller system files upon initialization. Integrated surge suppression combined with 1500 V isolation guards backplane bus communication velocity and processing logic against field voltage surges and electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power rails must be supplied to the IS200ACLEH1BCD module for operation?\u003c\/p\u003e\n\u003cp\u003eA: The card draws primary logic power directly from the 5 VDC system backplane bus at 400 mA to 600 mA, while external current loop driving requires an auxiliary 6 VDC to 30 VDC loop supply.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle firmware verification during system boot up?\u003c\/p\u003e\n\u003cp\u003eA: During backplane initialization, onboard non-volatile memory passes hardware ID indices to the host controller to confirm firmware flash compatibility before enabling channel outputs.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IS200ACLEH1BCD be removed or plugged in while the backplane power is active?\u003c\/p\u003e\n\u003cp\u003eA: No, field maintenance teams must fully de-energize the Mark VI rack backplane power supply prior to inserting or extracting the board to prevent backplane bus communication faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the IS200ACLEH1BCD card into its designated slot in the Mark VI rack enclosure, tightening mechanical card fasteners to verify solid chassis ground reference. Maintain ambient panel temperatures within the specified -30 deg C to +65 deg C operating window.\u003c\/p\u003e\n\u003cp\u003eRun signal cables using twisted-pair shielded conductors, bonding shields at a single ground bus bar within the panel enclosure. Route low-voltage analog cables clear of high-voltage lines to maintain signal purity. Always verify correct polarity on external 6 to 30 VDC power connections prior to energizing loop channels.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44442664009827,"sku":"IS200ACLEH1BCD","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/448._ce07b15d-9014-4023-9abe-c3089b74bbc0.jpg?v=1785912422","url":"https:\/\/www.autocontrolglobal.com\/products\/is200acleh1bcd-ge-mark-vi-application-control-layer-module","provider":"AutoControl Global","version":"1.0","type":"link"}