{"product_id":"is200epsmg2a-general-electric-ex2100-power-supply-module","title":"IS200EPSMG2A General Electric EX2100 Power Supply Module","description":"\u003ch2\u003eGeneral Electric IS200EPSMG2A EX2100 Exciter Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for Specific Technical Task in System\/Network Name, the \u003cstrong\u003eGeneral Electric IS200EPSMG2A\u003c\/strong\u003e (\u003cstrong\u003eIS200EPSMG2\u003c\/strong\u003e Exciter Power Supply Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EPSMG2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e80 mm x 186 mm x 261 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eProvides regulated DC power to exciter control boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e125 V DC nominal (range 100-140 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e+28 V DC regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple\/Noise\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 50 mV RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eInput-to-output isolation, withstand 1500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eOver-voltage, over-current, thermal shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eVME backplane monitoring signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupports simplex and redundant exciter configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Backplane Bus Infrastructure\u003c\/h3\u003e\n\u003cp\u003eThe module hardware interfaces directly with the system backplane to stream continuous diagnostic telemetry metrics. The internal microcontroller monitors power rails, output loading states, and internal thermal gradients, translating these data points into status words transmitted across the parallel backplane bus architecture. The integrated firmware architecture preserves flash compatibility parameters across the EX2100 and Mark VI topologies, responding deterministically to bus polling cycles. This localized intelligence tracks current draw deviations, isolating electrical faults at the modular interface level to avoid global data dropouts or execution lag across the primary controller network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module execute status monitoring across the turbine control system?\u003c\/p\u003e\n\u003cp\u003eA: The hardware routes specific analog and discrete diagnostic signals directly onto the VME backplane bus interface, enabling the central processor to scan voltage stability, load conditions, and fault registers during every logic execution frame.\u003c\/p\u003e\n\u003cp\u003eQ: What action occurs if the module operating temperature exceeds the designated 65 deg C threshold?\u003c\/p\u003e\n\u003cp\u003eA: Internal thermal sensor networks detect the baseline boundary violation and trigger an autonomous protective thermal shutdown circuit, which drops the +28 V DC output to protect downstream components and asserts an error flag on the backplane monitoring bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the module into the designated chassis slot using standard alignment rails, ensuring that the VME backplane connector engages fully before locking the module mechanical retention clips.\u003c\/li\u003e\n\u003cli\u003eTurn off all main input source power to the exciter subsystem before connecting or disconnecting the module terminal junctions to prevent electrostatic discharge (ESD) or high-voltage transient arcs.\u003c\/li\u003e\n\u003cli\u003eRoute the 125 V DC input power conductors through dedicated, shielded conduits, terminating the outer shield layer directly at the cabinet frame grounding bar to mitigate electromagnetic noise coupling.\u003c\/li\u003e\n\u003cli\u003eMaintain clear vertical clearance of at least 50 mm above and below the module enclosure to allow unimpeded convective airflow and prevent localized thermal stagnation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44375499276387,"sku":"IS200EPSMG2\/A","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/142_1b25adc0-5b03-4814-b9e9-337f63177a54.jpg?v=1784532324","url":"https:\/\/www.autocontrolglobal.com\/products\/is200epsmg2a-general-electric-ex2100-power-supply-module","provider":"AutoControl Global","version":"1.0","type":"link"}