IS200HSLAH2A GE Serial Interface Board
Manufacturer: GE Fanuc
-
Part Number: IS200HSLAH2A
Condition:New with Original Package
Product Type: Interface Boards
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
GE IS200HSLAH2A EX2100e Series
The GE IS200HSLAH2A, also cataloged as the IS200HSLA High-speed Serial Link Interface Board, operates as a dedicated hardware component for high-speed digital signal termination within Mark VIe and EX2100e control platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IS200HSLAH2A |
| Brand | GE |
| Origin | United States (USA) |
| Weight | 3.00 kg |
| Dimensions | 30.00 cm x 15.00 cm x 5.00 cm |
| Operating Temp | -40 to +70 deg C |
| Power Consumption | Driven by 28 VDC nominal backplane power |
| Channels | 16 digital I/O points |
| Response Time | < 1 ms for trip signals |
| Input Types | Dry contact, 24 VDC logic |
| Output Types | Relay / solenoid drivers (24-125 VDC) |
| Isolation | Channel-to-system and channel-to-channel isolation |
Industrial Control and Drive Technical Attributes
The board integrates with the deterministic backplane bus communication architecture to maintain sub-millisecond propagation delays for safety-critical trip loops. To ensure signal integrity across dense I/O scaling, the hardware utilizes optimized firmware flash compatibility profiles that synchronize channel states directly with the host processor. This synchronization eliminates transmission jitter and enforces deterministic network execution during transient turbine overspeed events.
Frequently Asked Questions
Q: What is the maximum propagation delay for critical trip signals through this board?
A: The board executes signal routing and termination with a deterministic response time of less than 1 ms to guarantee immediate safety-loop actuation.
Q: How is electrical noise suppressed between channels on the termination block?
A: Channel-to-channel and channel-to-system galvanic isolation barriers prevent cross-talk and eliminate ground loop interference in high-vibration turbine environments.
Field Installation Guidelines
- Mounting and Grounding: Secure the hardware onto standard DIN-rail or rack structures. Ensure the chassis ground terminal connects to the local master ground bus using a low-impedance copper conductor.
- Wiring Separation: Route high-voltage solenoid driver lines (up to 125 VDC) through separate physical conduits away from low-voltage 24 VDC logic and serial communication cables to eliminate electromagnetic interference.
- Shield Termination: Terminate all external field wiring shields at the designated grounding bar on the terminal board frame. Do not ground the shield at both ends to prevent circulating ground currents.